Phantom-Based Standardization Method for <sup>123</sup>I-meta-iodobenzylguanidine Heart-to-Mediastinum Ratio Validated by D-SPECT Versus Anger Camera

نویسندگان

چکیده

Background: The 123I-metaiodobenzylguanidine heart-to-mediastinum ratios (HMRs) have been standardized between D-SPECT and Anger cameras in a small patient cohort using phantom-based conversion method. This study aimed to determine the validity of this method compare diagnostic performance two larger cohort.Methods: We retrospectively calculated HMRs from early late anterior-planar equivalent planar images acquired 173 patients 177 studies cameras, respectively. were cross-calibrated an camera coefficients based on previous phantom findings, then medium-energy general-purpose collimator conditions. Relationships before after corrections investigated. Late classified into four cardiac mortality risk groups divided threshold 2.2 verify concordance.Results: Correction improved linear regression lines differences among groups. overall perfect concordance (134 [75.7%] 177), higher with very low (49 [80.3%] 61) high (51 [86.4%] 59) when HMR was according risk. That systems highest (164 [92.7%] 177) by value 2.2.Conclusions: Phantom-based can standardize because provided comparable performance. Our findings indicated that could be applied multicenter include both cameras.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cross calibration of 123I-meta-iodobenzylguanidine heart-to-mediastinum ratio with D-SPECT planogram and Anger camera

BACKGROUND Cardiac 123I-meta-iodobenzylguanidine (MIBG) uptake is quantified using the heart-to-mediastinum ratio (HMR) with an Anger camera. The relationship between HMR determined using D-SPECT with a cadmium-zinc-telluride detector and an Anger camera is not fully understood. Therefore, the present study aimed to define this relationship using images derived from a phantom and from patients....

متن کامل

Standardization of the heart-to-mediastinum ratio of iodine-123-labeled-meta-iodobenzylguanidine uptake using dual energy window method: Feasibility of correction from different camera-collimator combinations

Background. Although heart-to-mediastinum (H/M) ratio in a planner image has been used for practical quantification for I-metaiodobenzylguanidine (MIBG) imaging, standardization of the parameter is not yet established. We hypothesized that the value of H/M can be standardized to the various types of camera-collimator combinations. Methods and Results. Standard phantoms consisting of the heart, ...

متن کامل

Standardization of 123I-meta-iodobenzylguanidine myocardial sympathetic activity imaging: phantom calibration and clinical applications

PURPOSE Myocardial sympathetic imaging with 123I-meta-iodobenzylguanidine (123I-mIBG) has gained clinical momentum. Although the need for standardization of 123I-mIBG myocardial uptake has been recognized, the availability of practical clinical standardization approaches is limited. The need for standardization includes the heart-to-mediastinum ratio (HMR) and washout rate with planar imaging, ...

متن کامل

Meta-Iodobenzylguanidine Imaging: From Standardization to Mortality Risk Models in Heart Failure

123 I-meta-iodobenzylguanidine (MIBG) is a potent prognostic marker of chronic heart failure (CHF). However, inter-institutional variations due to methodological variations required minimization before 123 I-MIBG findings could be universally applied to the diagnosis, treatment and prognosis of CHF. Therefore, protocols including data acquisition, setting regions of interest for calculating hea...

متن کامل

A convenient Simple Method for Synthesis of Meta-iodobenzylguanidine (MIBG)

Radioiodinated meta iodobenzylguanidine (MIBG) is one of the important radiopharmaceuticals in Nuclear Medicine. [123/131I]MIBG is used for imaging of Adrenal medulla, studying heart sympathetic nerves, treatment of pheochromacytoma and neuroblastoma. For clinical application, radioiodinated MIBG is prepared through isotopic exchange method, which includes replacement of radioactive iodine in a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Annals of nuclear cardiology

سال: 2023

ISSN: ['2189-3926', '2424-1741']

DOI: https://doi.org/10.17996/anc.23-00003