PERSONAL RADIATION DETECTOR γ-TRACER GT2-1 WITH A CdZnTe DETECTOR
نویسندگان
چکیده
منابع مشابه
CdZnTe strip detector SPECT imaging with a slit collimator.
In this paper, we propose a CdZnTe rotating and spinning gamma camera attached with a slit collimator. This imaging system acquires convergent planar integrals of a radioactive distribution. Two analytical image reconstruction algorithms are proposed. Preliminary phantom studies show that our small CdZnTe camera with a slit collimator outperforms a larger NaI(Tl) camera with a pinhole collimato...
متن کاملCdZnTe detector in diagnostic x-ray spectroscopy.
A method to utilize CdZnTe (CZT) detectors in diagnostic x-ray spectroscopy is described in this article. Spectral distortion due to transmission of primary x rays, the escape of cadmium- and tellurium-K fluorescent x rays, and tailing was severe in measured x-ray spectra. Therefore, correction for the distortion was performed with the stripping method using response functions. The response fun...
متن کاملNuclear reactor pulse tracing using a CdZnTe electro-optic radiation detector
CdZnTe has previously been shown to operate as an electro-optic radiation detector by utilizing the Pockels effect to measure steady-state nuclear reactor power levels. In the present work, the detector response to reactor power excursion experiments was investigated. Peak power levels during an excursion were predicted to be between 965 MW and 1009 MW using the Fuchs–Nordheim and Fuchs– Hansen...
متن کاملMEASUREMENT OF DIAGNOSTIC X-RAY SPECTRA USING CdZnTe DETECTOR
INTRODUCTION We directly measured diagnostic X-ray photon spectra produced by a single-phase 2-pulse diagnostic X-ray unit driven at 50 to 100 kV and a few mA(1), a mammographic X-ray unit at 25 to 32 kV and 3 times of 80 mAs(2) and an X-ray computed tomography (CT) scanner at 120 kV and 3 mA(3) have been analyzed. Since detected spectra were distorted by the response of CdZnTe(CZT) detector an...
متن کاملA Fast, Robust, Automatic Blink Detector
Introduction “Blink” is defined as closing and opening of the eyes in a small duration of time. In this study, we aimed to introduce a fast, robust, vision-based approach for blink detection. Materials and Methods This approach consists of two steps. In the first step, the subject’s face is localized every second and with the first blink, the system detects the eye’s location and creates an ope...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: RAD Association Journal
سال: 2016
ISSN: 2466-4294
DOI: 10.21175/radj.2016.01.08