Perl-stent remodeling and neointimal response following intracoronary radiation therapy: a volumetric intravascular ultrasound study
نویسندگان
چکیده
منابع مشابه
Impact of peri-stent remodeling on restenosis: a volumetric intravascular ultrasound study.
BACKGROUND Vessel remodeling is an important mechanism of late lumen loss after nonstent coronary interventions. However, its impact on in-stent restenosis has not been systematically investigated. METHODS AND RESULTS Serial volumetric intravascular ultrasound analyses (poststent and follow-up) were performed in 55 lesions treated with a balloon-expandable stent (ACS MultiLink) using standard...
متن کاملLong-term vessel response to a self-expanding coronary stent: a serial volumetric intravascular ultrasound analysis from the ASSURE Trial.A Stent vs. Stent Ultrasound Remodeling Evaluation.
OBJECTIVES We sought to investigate the in vivo mechanical properties of a new self-expanding coronary stent (RADIUS) and, particularly, the subsequent vessel response over time. BACKGROUND Preclinical studies have suggested that self-expanding stents may produce less vessel wall injury at initial deployment, leading to larger follow-up lumens than with balloon-expandable stents. However, the...
متن کاملGeometric vascular remodeling after balloon angioplasty and beta-radiation therapy: A three-dimensional intravascular ultrasound study.
BACKGROUND Endovascular radiation appears to inhibit intimal thickening after overstretching balloon injury in animal models. The effect of brachytherapy on vascular remodeling is unknown. The aim of the study was to determine the evolution of coronary vessel dimensions after intracoronary irradiation after successful balloon angioplasty in humans. METHODS AND RESULTS Twenty-one consecutive p...
متن کاملEffects of intracoronary beta-radiation therapy after coronary angioplasty: an intravascular ultrasound study.
BACKGROUND Endovascular radiation is emerging as a potential solution for the prevention and treatment of restenosis. Its effects on the morphology of unstented vessels cannot be determined by angiography and therefore require the use of intravascular ultrasound. METHODS AND RESULTS Through a 5F noncentered catheter for delivery of a 90Sr/Y source train, 12, 14, or 16 Gy at 2 mm was delivered...
متن کاملDose heterogeneity may not affect the neointimal proliferation after gamma radiation for in-stent restenosis: a volumetric intravascular ultrasound dosimetric study.
OBJECTIVES The goal of this study was to use serial (postirradiation and follow-up) volumetric intravascular ultrasound (IVUS): 1) to evaluate the actual distribution of gamma radiation in human in-stent restenosis (ISR) lesions, and 2) to analyze the relationship between neointimal regrowth and the delivered radiation dose. BACKGROUND The relationship between the neointimal regrowth and deli...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the American College of Cardiology
سال: 2002
ISSN: 0735-1097