Peripheral Anterior Chamber Depth and Angle Measurements Using Pentacam After Implantation of Toric and Non-toric Implantable Collamer Lenses
نویسندگان
چکیده
منابع مشابه
Posterior Chamber Toric Implantable Collamer Lenses – Literature Review
Posterior Chamber Phakic Toric Implantable Collamer Lenses have become increasingly used to correct refractive error associated with astigmatism. These devices are claimed to provide high efficacy in terms of refractive correction. This book chapter is an updated review on the safety and effectiveness and potential complications of the toric implantable collamer lens (Toric ICL) published in pe...
متن کاملAnterior Chamber Changes After Implantable Collamer Lens Implantation in High Myopia Using Pentacam: A Prospective Study
INTRODUCTION The objective of this study was to evaluate the changes of the anterior chamber (AC) of the eye after implantable Collamer lens (ICL) implantation in high myopia by using the Pentacam. METHODS The prospective study included 34 high myopic patients (34 eyes). All patients were treated with Visian implantable Collamer lens (ICL) (Staar Surgical Co.) implantation. The Pentacam (Ocul...
متن کاملStability of axis and patient satisfaction after toric implantable collamer lens implantation for myopic astigmatism
OBJECTIVES To assess the stability of axis and patient satisfaction after toric visian implantable collamer lens (TICL) implantation for moderate to high myopic astigmatism. METHODS Total 33 eyes of 21 consecutive patients who underwent implantation of TICL for the correction of moderate to high myopic astigmatism were recorded and a minimum follow-up of six months was performed. The deviatio...
متن کاملAxis alignment and rotational stability after implantation of the toric implantable collamer lens for myopic astigmatism.
PURPOSE To assess axis alignment and stability of the Toric Implantable Collamer Lens (TICL; STAAR Surgical Co) over time. METHODS Thirty-five consecutive eyes of 19 patients received the TICL for treatment of myopic astigmatism. Manifest refraction spherical equivalent (MRSE) and manifest refractive cylinder were measured preoperatively and at 3 months postoperatively. The axis alignment of ...
متن کاملSpontaneous Rotation of a Toric Implantable Collamer Lens
We present a case of toric implantable collamer lens (TICL) spontaneous rotation in a patient with myopic astigmatism. A 23-year-old female underwent TICL implantation. Preoperative uncorrected visual acuity (UCVA) was 20/800 and 20/1200, respectively, with -7.75 -4.25 × 0° and -8.25 -5.25 × 180°. The left eye achieved an UCVA of 20/30. After 3 months of successful implantation of TICL in the l...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Frontiers in Medicine
سال: 2021
ISSN: 2296-858X
DOI: 10.3389/fmed.2021.610590