Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty
نویسندگان
چکیده
منابع مشابه
Perfusion MRI in hips with metal-on-metal and metal-on-polyethylene total hip arthroplasty: A pilot study.
OBJECTIVES Hips with metal-on-metal total hip arthroplasty (MoM THA) have a high rate of adverse local tissue reactions (ALTR), often associated with hypersensitivity reactions. Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) measures tissue perfusion with the parameter Ktrans (volume transfer constant of contrast agent). Our purpose was 1) to evaluate the feasibility of DCE-MRI ...
متن کاملCeramic Surface Engineered Metal-on-Metal Hips system for Total Hip Arthroplasty and Resurfacing Hip Arthroplasty
components for the reconstruction of the acetabulum and metal femoral head components for conventional THA and RHA. The ACCIS®metal components are made of a chrome-cobalt-molybdenum alloy, but are different from other metal-on-metal prostheses. The surfaces of the metal components are engineered with the ceramic Titanium-Niobium-Nitride (TiNbN) in order to minimize metal particulate wear, to pr...
متن کاملPainful metal-on-metal total hip arthroplasty.
Two patients were evaluated for the possibility of hypersensitivity to a Metasul articulation (Centerpulse, Austin, Tex) coupled with total hip arthroplasty. Serum was tested with a lymphocyte proliferation assay, and the capsular tissues from the hip were examined for perivascular lymphocytes. The diagnosis of hypersensitivity to Metasul could not be confirmed in these patients, and ultimately...
متن کاملComparison of Complications Following Revision of Metal-on-Metal Versus Metal-on-Polyethylene Total Hip Arthroplasty.
The aim of this study was to examine the clinical characteristics of patients who required revision and the rate of early complications after revision for metal-on-metal total hip arthroplasty (MOM THA) and metal-on-polyethylene total hip arthroplasty (MOP THA). Matched cohorts were selected by retrospective review from a single-center database of revision THAs for failed MOM and MOP THAs from ...
متن کاملPseudotumor associated with metal-on-polyethylene total hip arthroplasty.
This case report details the presentation, imaging results, and operative findings of a pseudotumor associated with a press-fit metal-on-polyethylene total hip arthroplasty (THA). An 80-year-old man presented approximately 7 years after undergoing THA with worsening right groin and lateral hip pain with an associated proximal thigh mass. Physical examination demonstrated a tender, large anterol...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Bone & Joint Research
سال: 2016
ISSN: 2046-3758
DOI: 10.1302/2046-3758.53.2000572