Calculation of the design parameters current transformers (CTs) is very complex due to their magnetic and thermal properties, complexity structure, different ferromagnetic properties materials nonlinearity B-H curve core material. The secondary output these used for both measurement protection circuits. Therefore, AT's accuracy must be good precise. In this study, transformer modeled as 2D using Finite Element Method (FEM). ANSYS@Maxwell program, which realizes a solution based on finite element method, has been in analysis transformer. Analyzes were carried out under open short circuit conditions. From results obtained from analysis, scattered electromagnetic flux distribution occurred transformer, caused CT erroneous. it observed that unwanted operating conditions occur circuits..
منابع مشابه
crystalline silicon solar cell engineering to improve fill factor, open circuit voltage, short circuit current and overall cell efficiency
design and optimization of a single crystalline silicon (c-si) solar cell is performed to achieve the maximum light conversion efficiency. various parameters such as doping concentration and thicknesses, and geometrical dimension of surface pyramids are studied. the inverted surface pyramid is used to increase the efficiency of the solar cell, and engineered oxide layer is used as the passivati...
متن کاملEddy Current Losses in Transformer Windings and Circuit Wiring
Skin Effect Figure 1 shows the magnetic field (flux lines) in and around a conductor carrying dc or low frequency current I. The field is radially symmetrical, as shown, only if the return current with its associated field is at a great distance. At low frequency, the energy in the magnetic field is trivial compared to the energy loss in the resistance of the wire. Hence the current Introductio...
متن کاملA New Circuit Topology for Open Circuit and Short Circuit Fault Tolerant Dc - Dc Converter
This paper describes a new design for a fault tolerant Hbridge dc-dc converter. Open circuit and short circuit fault tolerance is achieved using multilevel converter topology in combination with pulse width modulation control strategy allowing a large set of converter switching states to produce bidirectional power flows at any required output voltage. If two switches fail at particular instant...
متن کاملبررسی روش های تشخیص خطای ترانسفورماتور
power transformers are important equipments in power systems. thus there is a large number of researches devoted of power transformers. however, there is still a demand for future investigations, especially in the field of diagnosis of transformer failures. in order to fulfill the demand, the first part reports a study case in which four main types of failures on the active part are investigate...
Short-circuit boundary conditions in ferroelectric PbTiO3 thin films
We examine the application of short-circuit electrical boundary conditions in density-functional theory calculations of ferroelectric thin films. Modeling PbTiO3 films with metallic electrodes, we demonstrate that under periodic boundary conditions of supercells, short-circuit conditions for the electrodes are equivalently satisfied in two repeated slab geometries: a PbTiO3/metal superlattice g...