Performance Prediction and Working Fluid Active Design of Organic Rankine Cycle Based on Molecular Structure
نویسندگان
چکیده
Working fluid selection is crucial for organic Rankine cycles (ORC). In this study, the relationship between molecular structure and ORC performance was established based on quantitative structure–property (QSPR) working parameterized model (WFPM), from which an actively designed. First, QSPR with four properties, namely, critical temperature (Tc), boiling point (Tb), pressure (pc), isobaric heat capacity (cp0), built. Second, evaporation enthalpy (hvap), entropy (svap), thermal efficiency (η) were estimated by WFPM, results compared those using REFPROP to verify calculation accuracy of “QSPR+WFPM” coupling model. The average absolute relative deviations are below 8.44%. maximum error 6%. Then, thermodynamic limit corresponding thermophysical properties ideal calculated at typical geothermal source conditions. Finally, active design conducted Tc pc as target. research shows that C3H4F2 C4H3F5 optimal fluids 473.15 523.15 K sources, respectively.
منابع مشابه
Selection of the optimum prime mover and the working fluid in a regenerative organic rankine cycle
A regenerative organic Rankine cycle (RORC) is modeled and optimized for the use of waste heat recovery from a prime mover (PM). Three PMs including, a diesel engine, a gas engine, and a microturbine are selected in this study. Four refrigerants including isobutane, R123, R134a, and R245fa are selected. The nominal capacity of the PM, PM operating partial load, turbine inlet pressure, condenser...
متن کاملEffect of Working-fluid Mixtures on Organic Rankine Cycle System Performance: Heat Transfer and Cost Analysis
A thermodynamic limitation of single-component working fluids in organic Rankine cycles (ORCs) is the large exergy destruction (and, consequently, useful power loss) associated with evaporation and condensation. Due to their non-isothermal phasechange behaviour, non-azeotropic working-fluid mixtures have shown reduced exergy losses, leading to improved cycle efficiencies and power outputs. Thes...
متن کاملPerformance analysis and working fluid selection for geothermal energy-powered organic Rankine-vapor compression air conditioning
Results: The calculated results show that because of high system pressure for R290 and R134a, R600a is the more suitable working fluid for ORC in terms of expander size parameter, system efficiency and system pressure. In addition, R600a is also the most appropriate working fluid for VCC in terms of pressure ratio and coefficient of performance. R600 and R600a are more suitable working fluids f...
متن کاملPerformance analysis of organic Rankine cycle based on location of heat transfer pinch point in evaporator
The location of heat transfer pinch point in evaporator is the base of determining operating parameters of organic Rankine cycle (ORC). The physical mathematical model seeking the location of pinch point is established, by which, the temperature variations both of heat source and working fluid with UA can be obtained. Taking heat source with inlet temperature of 160 C as example, the matching p...
متن کاملPerformance and design optimization of a low-cost solar organic Rankine cycle for remote power generation
Recent interest in small-scale solar thermal combined heat and power (CHP) power systems has coincided with demand growth for distributed electricity supplies in areas poorly served by centralized power stations. One potential technical approach to meeting this demand is the parabolic trough solar thermal collector coupled with an organic Rankine cycle (ORC) heat engine. The paper describes the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energies
سال: 2022