Performance optimization of polymeric porous membrane-based liquid desiccant air dehumidifier used in air conditioning system
نویسندگان
چکیده
منابع مشابه
A Statistical Analysis of Desiccant Dehumidifier for Air Conditioning Application
Due to the direct utilization of thermal energy and possibility of using renewable energy resources, the interest of using desiccant wheels for air-conditioning application is increasing rapidly. The thermally driven desiccant cooling systems are environmental friendly and has a great potential to reduce the peak electricity demand. During the experiments the inlet and outlet parameters in the ...
متن کاملExperimental performance study of a proposed desiccant based air conditioning system
An experimental investigation on the performance of a proposed hybrid desiccant based air conditioning system referred as HDBAC is introduced in this paper. HDBAC is mainly consisted of a liquid desiccant dehumidification unit integrated with a vapor compression system (VCS). The VCS unit has a cooling capacity of 5.27 kW and uses 134a as refrigerant. Calcium chloride (CaCl2) solution is used a...
متن کاملParametric Analysis of a Rotary Type Liquid Desiccant Air Conditioning System
Now days, air conditioning systems are a must for almost every commercial and residential building to achieve comfortable indoor conditions. The increasing energy demand, and increasing oil prices and pollution levels raise the need for alternative air conditioning systems which can efficiently utilize renewable energy resources. The liquid desiccant-based air conditioning method is pollution f...
متن کاملTheoritical Study for Compact Liquid Desiccant Dehumidifier/regenerator System
Air may be dehumidified when it is brought into contact with a suitable liquid desiccant. Different types of liquid desiccants are available in the market and the application of the proper desiccant in hot humid climates would improve the dehumidification effectiveness. The driving potential for a dehumidification process is the difference in the pressure of the water vapor in the air and the w...
متن کاملFully Fresh Air Air-conditioning System Equipped with Double Heat Pipe Based Heat Recovery Technology
The using of double heat pipe based heat exchanger (HPHX) in a conventional fully fresh air air-conditioning (AC) system was examined in the present study. The fabricated HPHXs were tested under the actual conditions and the measured data were used to study the performance of the existing AC system (System A) and AC system equipped with the double HPHX (System B) for a yearly operation through ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Energy and Environmental Engineering
سال: 2019
ISSN: 2008-9163,2251-6832
DOI: 10.1007/s40095-019-00324-1