Performance of wood stud shear walls exposed to fire

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Seismic capacity rating and reliability assessment of wood shear walls

A modified version of the BRANZ procedure for lateral capacity rating of bracing walls is used to determine the sustainable lateral mass of a 910-mm wide ‘2x4’ wood shear wall. The key modifications involve: (1) the use of a multicriteria system identification method to determine a structural model that simultaneously fits test data from both cyclic testing and pseudo-dynamic testing; and (2) p...

متن کامل

Effects of Dead Load and Multiple Earthquake Loadings on Seismic Performance of Wood-Frame Shear Walls

Goals of this preliminary study are to better understand (1) earthquake performance of wood-frame shear walls carrying gravity loads, compared with walls without gravity load, and (2) performance of walls subjected to a sequence of earthquake motions, compared with walls subjected to a single earthquake. Tests with simulated earthquake ground motions were conducted on 2,440 by 2,440-mm (8 by 8-...

متن کامل

Seismic Performance Testing of Partially and Fully Anchored Wood-frame Shear Walls

Earthquake performance of wood-frame shear walls was evaluated by comparing fully and partially anchored walls under monotonic, cyclic, and earthquake loads and comparing with code measures. Suitability of monotonic and cyclic testing to predict seismic performance was examined. Earthquake tests were conducted on 2440-mm-square walls with Douglas-fir studs. Two oriented strandboard panels were ...

متن کامل

The Fire Performance of Exposed Timber Panels

Cross-laminated timber is increasingly being used in the construction of high-rise buildings due to its simple manufacturing system. In term of fire resistance, cross-laminated timber panels are promoted as having excellent fire resistance, comparable to that of non-combustible materials and to heavy timber construction, due to the ability of thick wood assemblies to char slowly at a predictabl...

متن کامل

Behaviour of Corroded Single Stud Shear Connectors

In this study, the effect of corrosion on the static behavior of stud shear connectors was investigated. An innovative test setup for single stud shear connectors was designed and established. Two series of specimens having different stud diameters were fabricated and tested. The test specimens were firstly corroded to different corrosion rates by the electronic accelerating method. Static load...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Fire and Materials

سال: 2000

ISSN: 0308-0501,1099-1018

DOI: 10.1002/(sici)1099-1018(200001/02)24:1<9::aid-fam693>3.0.co;2-6