Performance of the new vertex detector at SLD
نویسندگان
چکیده
منابع مشابه
The SLD VXD3 Detector and Its Initial Performance*
The SLD collaboration completed construction of a new CCD vertex detector (VXD3) in January 1996 and started data taking in April 1996 with the new system. VXD3 is an upgrade of the original CCD vertex detector, VXD2, which had successfully operated in SLD for three years. VXD3 consists of 96 large area CCDs, each having 3.2 million 20pmx 20pm pixels. By reducing the detector material and lengt...
متن کاملthe role of application of dynamic assessment approach in improvement of iranian efl writing performance at different language proficiency levels
the present study sought to investigate the role of dynamic assessment (da) in improvement of iranian efl writing performance at different language proficiency levels. to this end, after conducting the quick placement test, 60 iranian efl learners were assigned to two groups with different language proficiency levels. in both groups each participant wrote two compositions, one before and one af...
SVX’, the new CDF silicon vertex detector
The Collider Detector at Fermilab (CDF) radiation hardened silicon vertex detector (SVX’) is described. The new detector has several improvements over its predecessor such as better signal to noise and higher efficiency. It is expected to have a radiation tolerance in excess of 1 Mrad. It has been taking data for several months and some preliminary results are shown.
متن کاملVXD 3 : the SLD Vertex Detector Upgrade Based on a 307 MPixel CCD System
The SLD upgrade CCD vertex detector (VXD3) is described. Its 307 million pixels are assembled from 96 3.2 Mpixel CCDS of 13 cm2 each. The system has evolved from the pioneering CCD vertex detector VXD2, which has operated in SLD since 1992. The CCDS of VXD3 are mounted on beryllium ladders in three cylinders, providing three space point measurements along each track of about 5 microns resolutio...
متن کاملA Preliminary Measurement of R C Using the Sld Detector the Sld Collaboration*
We report a new measurement of R c using data obtained with the SLD detector in 1993-1996. This measurement uses a double tag technique, where the selection of a c hemisphere is based on the reconstructed mass of the charm hadron decay v ertex. The method utilizes the 3D vertexing capabilities of SLD's CCD vertex detectors and the small and stable SLC beams to obtain a high c-tagging eeciency a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Nuclear Science
سال: 1997
ISSN: 0018-9499,1558-1578
DOI: 10.1109/23.603716