Performance of second generation ICP-TOFMS for (multi-)isotope ratio analysis: a case study on B, Sr and Pb and their isotope fractionation behavior during the measurements
نویسندگان
چکیده
The second generation ICP-TOFMS is subject to IIF that does not follow the known mass dependent fractionation laws and possibly caused by non-mass and/or multiple processes with varying contributions.
منابع مشابه
a case study of the two translators of the holy quran: tahereh saffarzadeh and laleh bakhtiar
بطورکلی، کتاب های مقدسی همچون قران کریم را خوانندگان میتوان مطابق با پیش زمینه های مختلفی که درند درک کنند. محقق تلاش کرده نقش پیش زمینه اجتماعی-فرهنگی را روی ایدئولوژی های مترجمین زن و در نتیجه تاثیراتش را روی خواندن و ترجمه آیات قرآن کریم بررسی کند و ببیند که آیا تفاوت های واژگانی عمده ای میان این مترجمین وجود دارد یا نه. به این منظور، ترجمه 24 آیه از آیات قرآن کریم مورد بررسی مقایسه ای قرار ...
15 صفحه اولUranium Isotope Ratio Measurements with the NexION ICP-MS
One of the beneficial features of inductively coupled mass spectrometry (ICP-MS) is its ability to measure multiple isotopes of the same element. This ability is useful in many analyses, primarily as confirmation of a correct answer (i.e. if two isotopes of the same element give the same result, the result is most likely correct) or the ability to select another analytical isotope, if an interf...
متن کاملHIGH-PRECISION SILICON ISOTOPE RATIO MEASUREMENTS OF EARTH AND ENSTATITIC METEORITES AND IMPLICATIONS FOR Si ISOTOPE FRACTIONATION DURING CORE FORMATION
Introduction: Core formation processes in planets may impart stable isotope ratio signatures on the bulk silicate Earth due to partitioning between the metallic core and silicate [1]. Enstatite chondrites (E-chondrites) are the only primitive meteorite group with stable oxygen isotope compositions similar to Earth [2]. The Echondrites also possess a metal phase with substantial amounts of Si. W...
متن کاملThe performance of single and multi-collector ICP-MS instruments for fast and reliable 34S/32S isotope ratio measurements†
The performance and validation characteristics of different single collector inductively coupled plasma mass spectrometers based on different technical principles (ICP-SFMS, ICP-QMS in reaction and collision modes, and ICP-MS/MS) were evaluated in comparison to the performance of MC ICP-MS for fast and reliable S isotope ratio measurements. The validation included the determination of LOD, BEC,...
متن کاملthe relationship between learners critical thinking ability and their performance in the reading sections of the tofel and ielts test
the study reflected in this thesis aims at finding out relationships between critical thinking (ct), and the reading sections of tofel and ielts tests. the study tries to find any relationships between the ct ability of students and their performance on reading tests of tofel and academic ielts. however, no research has ever been conducted to investigate the relationship between ct and the read...
15 صفحه اولذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Analytical Atomic Spectrometry
سال: 2023
ISSN: ['1364-5544', '0267-9477']
DOI: https://doi.org/10.1039/d3ja00084b