Performance of polymer composite insulator and 154 kV insulation arm under polluted conditions
نویسندگان
چکیده
منابع مشابه
Performance Of EPDM Cable Terminations Under Various Polluted Conditions
Ethylene-Propylene-Diene Monomer (EPDM) insulators are used as indoor and outdoor insulators for high and medium voltage applications. This paper presents detailed investigations of the electrical properties of EPDM cable terminations. The effects of different environmental conditions (Dry and Wet at different salinities) under the effects of various levels of the ultraviolet (UV) radiation on ...
متن کاملDevelopment of a Live-line Insulator Inspection Tool System for 154 kV Power Transmission Lines
The current paper deals with a new live-line insulator inspection tool system that will be used by the Korea Electric Power Corporation for its 154 kV power transmission lines in 2011. Unlike the existing contact type tools, the developed inspection tool automates parts of the insulator inspection process using a sensor and an actuator. The tool sustains its weight independently, not by a linem...
متن کاملAn Experimental Investigation on Fracture Analysis of Polymer Matrix Composite under Different Thermal Cycling Conditions
Fracture analysis of glass/epoxy composites under different thermal cycling conditions is considered. Temperature difference, stacking sequence, fiber volume fraction and number of thermal cycles are selected as the experimental design factors. The Taguchi method is implemented to design of the experiment and an apparatus is developed for automatic thermal cycling tests. The tensile tests are d...
متن کاملdegradation of oil impregnated paper insulation under influence of repetitive fast high voltage impulses
در طی سالهای اخیراستفاده ازمنابع انرژی تجدید پذیر در شبکه های مدرن بنا به دلایل زیست محیطی و اقتصادی به طور گسترده استفاده شده است همچون نیروگاههای بادی و خورشیدی .ولتاژتولیدی این نیروگاهها اغلب به فرم dc می باشد وادوات الکترونیک قدرت به عنوان مبدل و پل بین شکل موج dc وac استفاده می شوند.این پروسه باعث ایجاد پالسهایی برروی شکل موج خروجی می شود که می تواند وارد تجهیزات قدرت همچون ترانسفورماتور ی...
15 صفحه اولElectric Field Analysis and Experimental Evaluation of 400 kV Silicone Composite Insulator
Abstract—In electrical power system, high voltage insulators are necessary for consistent performance. All insulators are exposed to different mechanical and electrical stresses. Mechanical stresses occur due to various loads such as wind load, hardware and conductors weight. Electrical stresses are due to over voltages and operating voltages. The performance analysis of polymer insulators is a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEJ Transactions on Power and Energy
سال: 1998
ISSN: 0385-4213,1348-8147
DOI: 10.1541/ieejpes1990.118.5_555