Performance of Optimized Generalized Weighted Estimator ICA algorithm on Biomedical Signals Contaminated by Noise
نویسندگان
چکیده
منابع مشابه
A Comparison of the Performance of ICA Algorithms for Fetal ECG Extraction using Time Domain Multiple-Sources Interference Data
This paper evaluates the performance of some major Independent Component Analysis (ICA) algorithms like Hyv ̈arinen’s fixed point algorithm, Pearson based ICA algorithm and OGWE (Optimized Generalized Weighted Estimator) ICA algorithm in a biomedical blind source separation problem. Independent signals representing Fetal ECG (FECG) and Maternal ECG (MECG) generated and then mixed linearly to sim...
متن کاملOn the Performance Analysis of the ICA Algorithms with Maternal and Fetal ECG signals Inputs and Contaminated Noises
This paper evaluates the performance of some major Independent Component Analysis (ICA) algorithms like Cardoso’s Joint Approximate Diagonalization of Eigen matrices (JADE), Comon’s algorithm and Optimized Generalized Weighted Estimator (OGWE) ICA algorithm in a biomedical blind source separation problem. Independent signals representing Fetal ECG (FECG) and Maternal ECG (MECG) are generated an...
متن کاملApplication of Ica for Automatic Noise and Interference Cancellation in Multisensory Biomedical Signals
Independent Component Analysis ICA and related meth ods like Adaptive Factor Analysis AFA are promising novel approaches for elimination of artifacts and noise from bio medical signals especially EEG MEG data However most of the methods require manual detection and classi cation of interference components Main objective of this paper is to detect and eliminate noise and some artifacts automat i...
متن کاملOn the Performance of a HOS-Based ICA Algorithm in BSS of Acoustic Emission Signals
A cumulant-based independent component analysis (CumICA) is applied for blind source separation (BSS) in a synthetic, multi-sensor scenario, within a non-destructive pipeline test. Acoustic Emission (AE) sequences were acquired by a wide frequency range transducer (100-800 kHz) and digitalized by a 2.5 MHz, 8-bit ADC. Four common sources in AE testing are linearly mixed, involving real AE seque...
متن کاملApplication of Weighted Myriad Filters to Suppress Impulsive Noise in Biomedical Signals
Abstract: Biomedical signals are commonly recorded with many kinds of noise. One of these is a waveform of the electrical activity of muscles. This “natural” distortion is usually modelled with a white Gaussian noise. In order to suppress such noise a weighted myriad filter is applied. The weighted myriad filter belongs to a class of non-linear filters and requires knowledge about noise impulsi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Computer Applications
سال: 2010
ISSN: 0975-8887
DOI: 10.5120/59-160