Performance of Novel U-Connector in CFS Truss-to-Column Bolted Connection under Axial Force

نویسندگان

چکیده

This paper presents an experimental and numerical investigation of the tensile compressive behaviour a novel U-connector in cold-formed steel (CFS) truss-to-column connection. Tensile tests were performed on 12 specimens representing tension chords trusses The results used to validate finite element model. validated model was then subjected both loads, which revealed low stiffness components proposed An optimisation geometry by using one long nut instead two nuts carried out improve optimised compared with data, conclusions drawn regarding effectiveness use long-nut compression connection shows significant increase load-bearing capacity, makes it very promising for future applications CFS connections. However, further validation through testing is required confirm reliability full-scale structures.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Review on Finite Element Analysis of Beam to Column Endplate Bolted Connection

This paper gives a bibliographical review of the methods which are applied for the analysis of Beam to column bolted end plate connection from the theoretical as well as practical points of view. The bibliography at the end of the paper contains 84 references of papers and conference proceedings on the subject that were published between 1914 and 2011. These are classified in the following cate...

متن کامل

Influential Factor in Improving the Seismic Performance of the Kaiser Bolted Bracket Moment Connection

Following the Northridge earthquake of 1994, a significant number of steel moment resisting structural systems were damaged. Several studies have been conducted to improve the seismic performance of steel structures and specially their beam-to-column connections. One of the proposed connections for special moment-resisting frames included AISC-358 is Kaiser bolted bracket moment connection, bri...

متن کامل

Performance of the Modified Precast Beam to Column Connection Placed on a Concrete Corbel

Precast concrete structures in Iran are generally designed as continuous columns with hinged beams, thereby making them simple frames. In this system in site show walls in two directions of buildings guaranteed lateral resisting system. However, in order to obtain a seismic resisting frame, the connection between beam and column should be moment resisting and ductile, allowing the formation of ...

متن کامل

Numerical Analysis of Cyclic Behavior of Beam-To-Column Bolted Connections in Steel Frames

This article considers the seismic behavior of beam-to-column joints in steel frames for different bolt arrangements by using of finite element modeling. As the most important beam-to-column joint type, the beam-to-column joints with end-plate is chosen for the analysis. Four different specimens have been analyzed. These models had some differences such as bolt arrangement and the presence or a...

متن کامل

Seismic Behavior of Prefabricated Column-Footing Connection

Results of an experimental investigation of the seismic performance of prefabricated column-footing connections are presented. Tests were conducted on six 1/4-scale prefabricated column specimens inserted into prefabricated footings in two Groups. Group-1 consisted of four specimens, which were tested under constant axial load and cyclic inelastic lateral displacements. The remaining two specim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Buildings

سال: 2023

ISSN: ['2075-5309']

DOI: https://doi.org/10.3390/buildings13071623