Performance of Mixed Flow Multiblade Fan as Small Duct Fan
نویسندگان
چکیده
منابع مشابه
Flows in Duct for Axial Fan
Axial flow fan has been used for large amount of flow rate in air handling units of industrial application fields. The fan involves a shrouding duct as flow guidance for uniform flows. Pressure difference between before and ahead of rotating blades causes the flows movements. The case where the flow resistance such as a heat exchanger is located prior to the rotors is typical in-field model for...
متن کاملAerodynamic Performance of Fan-Flow Deflectors for Jet-Noise Reduction
This paper presents a computational study on the aerodynamic effectiveness of vane-type fan-flow deflectors used for reducing jet noise from a supersonic turbofan exhaust with bypass ratio of 2.7. The numerical code solved the three-dimensional Reynolds-averaged Navier–Stokes equations. A series of nozzle configurations using deflector vanes of variable number, airfoil section, azimuthal mounti...
متن کاملInfluence of Chord Lengths of Splitter Blades on Performance of Small Axial Flow Fan
On the basis of small axial fan with five blades, 6 types of small axial flow fans with different chord lengths splitter blades were designed. Numerical simulation of 6 fan models with splitter blades and prototype fan were done by using Fluent. Based on the obtained simulation results, internal flow characteristics and aerodynamic noise were analyzed and compared. It indicates that: splitter b...
متن کاملFan Flow Deflection for Supersonic Turbofan Engines
We present an initial parametric investigation of fan flow deflectors for suppressing noise from supersonic turbofan engines. Realistic exhaust geometry and flow conditions for bypass ratio 2.7 were simulated in a subscale experiment. The study encompassed acoustic measurement and mean velocity surveys. The deflectors comprised internal vanes with both symmetric and cambered airfoil sections an...
متن کاملFan Flow Deflection in Simulated Turbofan Exhaust
Fan flow deflection for jet noise reduction was applied to subscale nozzles simulating the geometry and exhaust conditions of separate-flow turbofan engines. Two types of deflectors were tested, one comprising two pairs of vanes internal to the fan duct and the other consisting of a wedge positioned outside the fan duct. The noise reduction achieved by the vanes was strong in the downward direc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Transactions of the Japan Society of Mechanical Engineers Series B
سال: 1997
ISSN: 1884-8346,0387-5016
DOI: 10.1299/kikaib.63.611_2386