Performance of Low Voltage Ride-Through Protection Techniques for DFIG Wind Generator.(Dept.E)

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Voltage Compensation Using UPQC For DFIG Wind Turbine Low - Voltage Ride - Through Solution

This paper describes the problem of voltage sags and swells and its severe impact on sensitive loads and introduces a new solution for doubly fed induction generators to stay connected to the grid during voltage sags. The main idea is to increase the stator voltage to a level that creates the required flux to keep the rotor side converter current below its transient rating. To accomplish this g...

متن کامل

Low voltage ride-through capability improvement of DFIG-based wind turbines under unbalanced voltage dips

This paper proposes a competent and effective scheme to enhance the ride-through capability of DFIGbased wind turbines under unbalanced voltage dip conditions. The proposed method is realized through joint use of the rotor-side converter control and a three-phase stator damping resistor (SDR) placed in series with the stator windings. By means of an asymmetrical SDR idea, during the unbalanced ...

متن کامل

Fast Coordinated Control of DFIG Wind Turbine Generators for Low and High Voltage Ride-Through

This paper presents a fast coordinated control scheme of the rotor side converter (RSC), the Direct Current (DC) chopper and the grid side converter (GSC) of doubly fed induction generator (DFIG) wind turbine generators (WTGs) to improve the low voltage ride through (LVRT) and high voltage ride through (HVRT) capability of the DFIG WTGs. The characteristics of DFIG WTGs under voltage sags and s...

متن کامل

Low Voltage Ride through Capability Improvement of Dfig Based Wind Turbine Using Statcom

This paper studies a control strategy to improve low voltage ride through (LVRT) capability of doubly fed induction generator (DFIG)-based wind turbine (WT). This solution is based on the DFIG with Crowbar circuit control and the installation of STATCOM which is connected at the point of common coupling (PCC). The simulation model of WTs with STATCOM is built using the environment MATLAB/Simuli...

متن کامل

Low Voltage Ride Through Enhancement Based on Improved Direct Power Control of DFIG under Unbalanced and Harmonically Distorted Grid Voltage

In the conventional structure of the wind turbines along with the doubly-fed induction generator (DFIG), the stator is directly connected to the power grid. Therefore, voltage changes in the grid result in severe transient conditions in the stator and rotor. In cases where the changes are severe, the generator will be disconnected from the grid and consequently the grid stability will be attenu...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: MEJ. Mansoura Engineering Journal

سال: 2021

ISSN: 2735-4202

DOI: 10.21608/bfemu.2021.156994