Performance of composite geogrid reinforced unpaved pavements under cyclic loading
نویسندگان
چکیده
This paper presents an experimental study on evaluating the performance of composite geogrid (CGG) reinforced and unreinforced unpaved pavement models using a steel box that has length width height 1.0 m 1.2 respectively. A subgrade CBR 2.5% (unsoaked) was prepared to thickness 500 mm, then granular base compacted top subgrade. Three course thicknesses, namely 200 300 mm 400 were adopted in this study. Pavement subjected repeated loading with maximum pressure 550 kPa. The test results suggest thick performs better compared bases. Furthermore, CGG reinforcement is effective decreasing deformation also reducing vertical stresses weak for thinner pavements. Nevertheless, potential benefits diminish increase because would act as rigid boundary, failure occur above layer.
منابع مشابه
Laboratory Evaluation of Geogrid-Reinforced Flexible Pavements
.............................................................................................................................. III ACKNOWLEDGMENTS ........................................................................................................... V TABLE OF CONTENTS .......................................................................................................... VII LIST OF FIG...
متن کاملExperimental Evaluation of Performance Criteria for Reinforced Concrete Beams under Cyclic Loading
To assess the performance criteria of the reinforced-concrete, five-storey residential buildings common in Iran, an 
experimental study in the structural laboratory of the University of Tehran has been conducted. The test program includes cyclic and monotonic load tests of six beams that represent three-to-five storey buildings with rigid frame structures. Using definitions given in FEMA-356...
متن کاملExperimental Evaluation of Performance Criteria for Reinforced Concrete Beams under Cyclic Loading
To assess the performance criteria of the reinforced-concrete, five-storey residential buildings common in Iran, an experimental study in the structural laboratory of the University of Tehran has been conducted. The test program includes cyclic and monotonic load tests of six beams that represent three-to-five storey buildings with rigid frame structures. Using definitions given in FEMA-356 a...
متن کاملSimulation of Highly Ductile Fiber - Reinforced Cement - Based Composite Components Under Cyclic Loading
Ductile fiber-reinforced cement-based composites (DFRCCs) are being investigated for new design as well as retrofitting of structures in seismic regions. DFRCC is highly ductile and is characterized by strain-hardening in tension to strains over 3% and by unique cyclic loading behavior. To accurately predict the structural performance of DFRCC components under cyclic and seismic loading, a robu...
متن کاملBehaviour of Reinforced Fibrous Concrete Beams under Reversed Cyclic Loading
When earthquakes occur, energy released by the earthquake gets induced into the structure as ground motion and this energy has to be dissipated for safety reasons. To release seismic energy, the structure should damage in such a way that on one hand, collapse of structure should not occur and on the other hand, after the earthquake, damage should be economically feasible to repair. To avoid the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Construction and Building Materials
سال: 2021
ISSN: ['1879-0526', '0950-0618']
DOI: https://doi.org/10.1016/j.conbuildmat.2021.124570