Performance of bolted steel-beam to CFST-column joints using stiffened angles in column-removal scenario

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Numerical Analysis of Cyclic Behavior of Beam-To-Column Bolted Connections in Steel Frames

This article considers the seismic behavior of beam-to-column joints in steel frames for different bolt arrangements by using of finite element modeling. As the most important beam-to-column joint type, the beam-to-column joints with end-plate is chosen for the analysis. Four different specimens have been analyzed. These models had some differences such as bolt arrangement and the presence or a...

متن کامل

numerical analysis of cyclic behavior of beam-to-column bolted connections in steel frames

this article considers the seismic behavior of beam-to-column joints in steel frames for different bolt arrangements by using of finite element modeling. as the most important beam-to-column joint type, the beam-to-column joints with end-plate is chosen for the analysis. four different specimens have been analyzed. these models had some differences such as bolt arrangement and the presence or a...

متن کامل

A Study on the Ductility of Bolted Beam - Column Connections

The behaviour of beam-column joint plays an important role in the response of a steel moment resisting framed structure especially under seismic excitation. Semi rigid connections like bolted joints, allow better energy dissipation and provide good response under lateral loads. In this paper the ductility and energy dissipation characteristics of semi rigid bolted connections using double web a...

متن کامل

Strengthening of defected beam–column joints using CFRP

This paper presents an experimental study for the structural performance of reinforced concrete (RC) exterior beam-column joints rehabilitated using carbon-fiber-reinforced polymer (CFRP). The present experimental program consists of testing 10 half-scale specimens divided into three groups covering three possible defects in addition to an adequately detailed control specimen. The considered de...

متن کامل

Retrofitting of Beam-Column Joint Using CFRP and Steel Plate

─This paper presents the retrofitting of beam-column joint using CFRP (Carbon Fiber Reinforced Polymer) and steel plate. This specimen was tested until failure up to 1.0% drift. This joint suffered severe damages and diagonal cracks at upper crack at upper column before retrofitted. CFRP were wrapped at corbel, bottom and top of the column. Steel plates with bonding were attached to the two bea...