Performance of an Axial Gas Ionization Detector
نویسندگان
چکیده
منابع مشابه
A surface ionization detector for capillary gas chromatography.
A novel surface ionization detector using a reducing quartz liner and a Mo emitter with a quartz enclosed internal heater for selective measurement of alkylamines by gas chromatography is designed and evaluated.
متن کاملCalorimetric Ionization Detector
A new mode of operation for ionization detectors is described. The amount of ionization produced in a detector is detennined by measuring the amount of heat generated during the carrier collection process. Very high detection sensitivities, including single carrier detection, may be achieved at cryogenic temperatures. Results from an experimental device operated at T=O.3K is presented.
متن کاملTheory of Gas Ionization by Intense Electromagnetic Fields
The distribution function of the electrons produced in the interaction between an intense electromagnetic wave and a neutral gas is derived and is shown to be nonequilibrium and anisotropic. By assuming that the time scale of gas ionization is much greater than the field period, it is shown that the electron distribution function formed in microwave and optical discharges has sharp anisotropy a...
متن کاملIonization of Infalling Gas
Hα emission from neutral halo clouds probes the radiation and hydrodynamic conditions in the halo. Armed with such measurements, we can explore how radiation escapes from the Galactic plane and how infalling gas can survive a trip through the halo. The Wisconsin H-Alpha Mapper (WHAM) is one of the most sensitive instruments for detecting and mapping optical emission from the ISM. Here, we prese...
متن کاملDirect analysis of artemisinin from Artemisia annua L. using high-performance liquid chromatography with evaporative light scattering detector, and gas chromatography with flame ionization detector.
Since the isolation of artemisinin 32 years ago, it has been analyzed by different chromatographic techniques. This work compared the analysis of artemisinin from crude plant samples by GC with flame ionization detection (GC-FID) and HPLC with evaporative light scattering detector (HPLC-ELSD). Data is also presented indicating that GC is suitable for the quantification of two of artemisinin pre...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Nuclear Science
سال: 2006
ISSN: 0018-9499
DOI: 10.1109/tns.2006.878132