Performance of a lead radiator, gas tube calorimeter
نویسندگان
چکیده
منابع مشابه
Design and Performance of the Asp Lead-glass Calorimeter*
The design of the ASP detector is described and details of the construction and performance of the lead-glass tracking calorimeter are presented. ASP, a non-magnetic particle detector, was used at the PEP e+estorage -.-. ring at ,/X = 29 GeV to study low-multiplicity final states consisting primarily of electrons and photons. The design utilized extruded lead-glass bars to obtain a compact elec...
متن کاملThe HADES lead glass calorimeter
J.Pietraszko1, L. Fabbietti2, F. Guber3, A. Ivashkin3, A. Kugler4, K. Lapidus2, E. Lisowski6, A. Reshetin3, P. Salabura5, Yu.G. Sobolev4, P. Tlusty4, and the HADES collaboration.. 1Institut für Kernphysik, Goethe-Universität Frankfurt, Germany; 2Excellence Cluster Origin and Structure of the Universe, 85748 München, Germany; 3Institute for Nuclear Research, Russian Academy of Science, 117312 Mo...
متن کاملPerformance of a C4F8O Gas Radiator Ring Imaging Cherenkov Detector Using Multi-anode Photomultiplier Tubes
We report on test results of a novel ring imaging Cherenkov (RICH) detection system consisting of a 3 meter long gaseous C4F8O radiator, a focusing mirror, and a photon detector array based on Hamamatsu multi-anode photomultiplier tubes. This system was developed to identify charged particles in the momentum range from 3-70 GeV/c for the BTeV experiment. PACS numbers: 03.30+p, 07.85YK
متن کاملThe CMS Lead Tungstate Electromagnetic Calorimeter
The CERN LHC will open a new regime in the exploration of fundamental interactions. Of central importance to these studies will be the precise measurement of high energy electrons and photons. The CMS experiment therefore incorporates a high resolution electromagnetic calorimeter comprising 76000 lead tungstate crystals, covering almost 4pi, and capable of operating reliably for ten years in a ...
متن کاملLead exposure in radiator repair workers: a survey of Washington State radiator repair shops and review of occupational lead exposure registry data.
Radiator repair workers in Washington State have the greatest number of very elevated (> or =60 microg/dL) blood lead levels of any other worker population. The goals of this study were to determine the number of radiator repair workers potentially exposed to lead; estimate the extent of blood lead data underreporting to the Occupational Lead Exposure Registry; describe current safety and healt...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Nuclear Science
سال: 1989
ISSN: 0018-9499,1558-1578
DOI: 10.1109/23.34407