Performance of a beam telescope using double sided silicon microstrip detectors
نویسندگان
چکیده
منابع مشابه
Universit . . at Bonn Physikalisches Institut Performance of a Beam Telescope Using Double Sided Silicon Microstrip Detectors ?
A beam telescope consisting of four double sided, DC coupled microstrip detectors with VLSI readout electronics has been built and tested in a 70 GeV ? beam at CERN. A signal to noise ratio of 53:1 and a spatial resolution of 2.7m (junction side) and 4.8m (ohmic side) have been observed on the best detectors. A telescope performance for a particle track of xy = 2 ? 3 m and slope = 2 ? 3 rad on ...
متن کاملPerformance on test beam of the L3 double-sided silicon microstrip detector
Disclaimer/Complaints regulations If you believe that digital publication of certain material infringes any of your rights or (privacy) interests, please let the Library know, stating your reasons. In case of a legitimate complaint, the Library will make the material inaccessible and/or remove it from the website. Please Ask the Library: http://uba.uva.nl/en/contact, or a letter to: Library of ...
متن کاملSimulation study of radiation damage in double-sided silicon microstrip detectors for the CBM Silicon Tracking System
We started TCAD simulations last year to understand the radiation damage in Double Sided Silicon Strip Detectors (DSSD) for the CBM Silicon Tracking System. We used the public domain versions from Stanford namely SUPREM for Process Simulation and PISCES for device simulation [1]. The results were reported in the GSI Scientific Report 2008 [2]. Now we are using the three-dimensional TCAD simulat...
متن کاملDouble-sided Silicon Detectors using N-side Pad Readout for the CMS Silicon Inner Tracker
Double-sided silicon detector prototypes produced for the CMS inner tracker are described which divide the n-side into pads rather than strips. The signal routing to the readout electronics is made on a separate flexible z-print which is glued on the detector and then wire-bonded to the pads.
متن کاملBeam Test of the SDC Double-sided Silicon Strip Detector
A beam test was executed to evaluate the behavior of the first prototype radiation-hard double-sided silicon microstrip sensor for the SDC silicon tracking system. Pions of 4 GeV/c in a test beamline at KEK illuminated three planes of detectors. The signals were amplified, shaped, and discriminated with TEKZ bipolar analog LSI's, and the on-off levels were sampled at 10MHz clock with CMOS digit...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
سال: 1995
ISSN: 0168-9002
DOI: 10.1016/0168-9002(95)00489-0