Performance of 420 kV Instrument Transformers under Earthquake

نویسندگان

چکیده

Seismic performance of substation equipment during past earthquakes is poor. In addition, requirement electric power post-earthquake led to an increased focus on the earthquake survivability equipment. Equipment installed in vulnerable by virtue its geometry and configuration. Interconnection between further aggravates problem. Failure results financial loss considerable time required repair/replace restore supply. Earthquake vibration level can be evaluated based site/location but predicting occurrence not possible. High voltage shall designed for seismic loading. Foundation, anchoring, installation interconnection also need engineered according load location qualification various as per National International standard performed using tri-axial shake table facility Engineering Vibration Research Centre. Performance 420kV instrument transformers under environment presented this paper.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Solid insulation drying of 110 kV paper-oil instrument transformers

Influence of moisture on the instrument transformers’ paper-oil insulation and its further maintenance is described in this paper. Improved insulation drying method using vacuum and temperature regulation with definite regulation algorithm of parameters is proposed and analyzed by comparing it with conventional drying method.

متن کامل

Ferroresonance in Power and Instrument Transformers

This chapter describes the fundamental concepts of ferroresonance phenomenon and analyzes its symptoms and the consequences in transformers and power systems. Due to its nonlinear nature, the ferroresonance phenomenon can result in multiple oscillating modes which can be characterized based on the concepts of the nonlinear dynamic systems, e.g., Poincare map. Among numerous system configuration...

متن کامل

Calibration of Instrument Current Transformers with Atypical Secondary Current

− Methods enabling a determination of errors εI and δI for a high transformation ratio difference between a standard and tested instrument current transformers (ICT) are described in this article. A widespread method uses an automatic transformer test set for the measurement of a difference between a standard and tested ICT. A method transforming secondary currents to voltages and an indirect m...

متن کامل

Development of non-conventional instrument transformers (NCIT) using smart materials

In this paper is presented a novel approach for current measurement using smart materials, magnetic shape memory (MSM) alloys. Their shape change can be controlled by the application of magnetic field or mechanical stress. This gives the possibility to measure currents by correlating the magnetic field produced by the current, shape change in an MSMbased sensor and the voltage output of a Linea...

متن کامل

A graphical instrument for performance analysis of contractors

The relationship between the manufacturer and supplier has changed from one of competition into that of greater cooperation during recent years. The selection and evaluation of suppliers are primary and important issues when an enterprise implements Supplier Relationship Management (SRM) and Total Quality Management (TQM). Much research indicates that most enterprises tend to evaluate their sup...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: The Journal of CPRI

سال: 2023

ISSN: ['0973-0338']

DOI: https://doi.org/10.33686/pwj.v19i1.1114