Performance improvement of water-cooled screw chiller under part load operation conditions by the paralleling throttle mechanism
نویسندگان
چکیده
منابع مشابه
Optimization of Water - Cooled Chiller – Cooling Tower Combinations
Water-cooled chiller systems have typically been designed around entering condenser water temperatures of 85°F with a Optimization of Water Cooled Chiller – Cooling Tower Combinations The warm water leaving the chilled water coils is pumped to the evaporator of the chiller, where the unwanted heat from the building is transferred by the latent heat of vaporization of the refrigerant. The compre...
متن کاملToward an Improvement of Natural Gas-diesel Dual Fuel Engine Operation at Part Load Condition by Detail CFD Simulation
Natural gas-diesel dual fuel combustion is a beneficial strategy for achieving high efficient and low emissions operation in compression ignition engines, especially in genset application heavy duty diesel engine at rated power. This study aims to investigate a dual fuel engine performance and emissions using premixed natural gas and early direct injection of diesel fuel. Due to the different r...
متن کاملParalleling Dissimilar Generators: Part 3 – Load Sharing Compatibility
Generator sets cannot operate in a stable fashion in parallel with other sources unless the loading on the generator set is controlled. When generator sets are operating together on an isolated bus (that is, not grid-paralleled), they are commonly provided with equipment to allow each machine to operate at the same percentage of load as the percentage of load on the total system. This is termed...
متن کاملDevice Performance Improvement of Double-Pass Wire Mesh Packed Solar Air Heaters under Recycling Operation Conditions
Abstract: The improvement of device performance of a recycling solar air heater featuring a wire mesh packing was investigated experimentally and theoretically. The application of the wire mesh packing and recycle-effect concept to the present study were proposed aiming to strengthen the convective heat-transfer coefficient due to increased turbulence. Comparisons were made among different desi...
متن کاملImproving the performance of UPQC under unbalanced and distortional load conditions: A new control method
This paper presents a new control method for a three-phase four-wire Unified Power Quality Conditioner (UPQC) to deal with the problems of power quality under distortional and unbalanced load conditions. The proposed control approach is the combination of instantaneous power theory and Synchronous Reference Frame (SRF) theory which is optimized by using a self-tuning filter (STF) and without us...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Thermal Science
سال: 2018
ISSN: 0354-9836,2334-7163
DOI: 10.2298/tsci171011043n