Performance evaluation of impinging jet ventilation combined with ductless personalized ventilation

نویسندگان

چکیده

Impinging jet ventilation (IJV), which supplies a high momentum air impinging and spreading over the floor, could be used in both cooling heating modes. However, as low-level supply system, excessive temperature difference between head ankle levels may exist due to cool being directly supplied occupied zone. As one type of different personalized (PV) terminal device, ductless (DPV) is self-standing system doesn’t require an extended duct. In this study, numerical simulation was assess performance DPV combined with IJV office buildings under operating parameters. The results show that large occupant’s will significantly decreased by application while not influencing stratification characteristics ventilation.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Jet ventilation through jet stylets.

To the Editor-The case report by Baraka’ of jet ventilation through an airway exchange catheter (Cook Critical Care, Bloomington, IL) complicated by tension pneumothorax and cardiac asystole highlights some of the serious dangers of jet ventilation. I would like to focus on three aspects of the case report. The lessons from these can be added to the recommendations made by Baraka at the end of ...

متن کامل

High - frequency Jet Ventilation

High-frequency jet ventilation (HFJV) describes a technique of mechanical respiratory support based on the delivery of gases under conditions of constant flow and low pressure. Among the benefits ascribed to HFJV are lessened interference with hemodynamic function and reduced danger of barofrauma. The theoretical and technical aspects of HFJV are discussed and the clinical experience with 39 pa...

متن کامل

Comparison of superimposed high-frequency jet ventilation with conventional jet ventilation for laryngeal surgery.

BACKGROUND New ventilators have simplified the use of supraglottic superimposed high-frequency jet ventilation (SHFJV(SG)), but it has not been systematically compared with other modes of jet ventilation (JV) in humans. We sought to investigate whether SHFJV(SG) would provide more effective ventilation compared with single-frequency JV techniques. METHODS A total of 16 patients undergoing min...

متن کامل

COMPARING k-ε MODELS ON PREDICTIONS OF AN IMPINGING JET FOR VENTILATION OF AN OFFICE ROOM

The objective of this study is to compare the performance of different k-ε models, i.e. the Standard k-ε, the Renormalization Group (RNG) k-ε, and the Realizable k-ε, with a two-layer model for the prediction of the mean velocity field and the temperature pattern from a newly designed impinging jet supply device for ventilation of an office room. The numerical predictions are validated against ...

متن کامل

Evaluation of Troponin-T level in Neonate with Mechanical Ventilation

Introduction: Troponin- T is the best biological marker of heart injuries, that isn’t affected by sex, age, birth weight and gestational age. Myocardial damage in infancy is a risk factor eventual cardiac disease. This study carried out for cardiac evaluation of neonates with mechanical ventilation by Troponin T. Methods: This case-control study carried out on 60 infants that were admitte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: E3S web of conferences

سال: 2022

ISSN: ['2555-0403', '2267-1242']

DOI: https://doi.org/10.1051/e3sconf/202235601052