Performance Evaluation of Field-In-Field Technique for Tangential Breast Irradiation

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance evaluation of field-in-field technique for tangential breast irradiation.

Conventional hard or dynamic wedge systems are commonly applied to reduce the dose inhomogeneity associated with whole breast irradiation. We evaluated the dosimetric benefits of the field-in-field (FIF) technique by comparing it with the electronic compensator (EC), Varian enhanced dynamic wedge (EW) and conventional hard wedge (HW) techniques. Data were obtained from 12 patients who had under...

متن کامل

Evaluation of the field-in-field technique with lung blocks for breast tangential radiotherapy

Several studies have reported the advantages of the field-in-field (FIF) technique in breast radiotherapy, including dose reduction in the lungs by using lung field blocks. We evaluated the FIF technique with lung blocks for breast tangential radiotherapy. Sixteen patients underwent free breathing (FB) computed tomography (CT), followed by two CT procedures performed during breath hold after li...

متن کامل

Impact of respiratory motion on breast tangential radiotherapy using the field-in-field technique compared to irradiation using physical wedges

BACKGROUND This study aimed to evaluate whether the field-in-field (FIF) technique was more vulnerable to the impact of respiratory motion than irradiation using physical wedges (PWs). PATIENTS AND METHODS Ten patients with early stage breast cancer were enrolled. Computed tomography (CT) was performed during free breathing (FB). After the FB-CT data set acquisition, 2 additional CT scans wer...

متن کامل

Determination of the optimal method for the field-in-field technique in breast tangential radiotherapy

Several studies have reported the usefulness of the field-in-field (FIF) technique in breast radiotherapy. However, the methods for the FIF technique used in these studies vary. These methods were classified into three categories. We simulated a radiotherapy plan with each method and analyzed the outcomes. In the first method, a pair of subfields was added to each main field: the single pair of...

متن کامل

Effects of Setup Errors on Dose Distribution for Tangential Wedge Field and Field-in-Field Techniques During Breast Irradiation

This study is aimed to evaluate the effects of setup errors on dose distribution for target volume and healthy tissue within the irradiated volume and also critical surrounding organs for breast radiotherapy (RT) using both the tangential field and the field-in-field (FIF) technique. Ten patients with breast cancer were enrolled. For each patients two plans were generated; tangential field plan...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Japanese Journal of Clinical Oncology

سال: 2008

ISSN: 0368-2811,1465-3621

DOI: 10.1093/jjco/hym167