Performance Evaluation of an Imaging Radiation Portal Monitor System

نویسندگان

چکیده

An organic scintillator-based radiation portal monitor (RPM) prototype system with imaging capabilities has been developed based on the neutron–gamma emission tomography technique. The technique enables rapid detection and precise location of small amounts special nuclear materials, such as plutonium, using time energy correlations between fast neutrons gamma rays from spontaneous fission low false-alarm rates. These capabilities, in addition to state-of-the-art various gamma-emitting sources, novel RPM concept efficiently address global security threats terrorism proliferation weapons. detector approach is simple versatile can easily be adapted for different applications security, public safety, emergency response, radiological surveying. In this work, basic performance parameters at KTH have evaluated.

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of the Portal Imaging System Performance for an Elekta Precise Linac in Radiotherapy

Introduction: Electronic portal imaging devices (EPIDs) provide two- and three-dimensional planar and volumetric cone beam images to improve the accuracy of radiation treatment delivery. Periodic quality assurance (QA) of EPIDs is essential for dosimetric verification in radiotherapy. In this study, a QA program was implemented to evaluate the function of the EPID to be confident in applying co...

متن کامل

Utilizing an electronic portal imaging device to monitor light and radiation field congruence

A method to investigate light and radiation field congruence utilizing a commercially available amorphous silicon electronic portal imaging device (EPID) was developed. This method employed an EPID, the associated EPI software, and a diamond-shaped template. The template was constructed from a block tray in which Sn/Pb wires, 1 mm in diameter, were embedded into a diamond shaped groove milled i...

متن کامل

Analytical Performance and Quality Control of a Glucose Monitor System

  Background and Objective: The reliability and validity of monitors for self-monitoring of blood glucose are debated. We evaluated the analytical performance of Accu-check Active (Boehringer Mannheim, Roche) which is one of the most commonly used monitors in Iran. Material and Methods: We compared the monitor readings with the reference values by percentage of values within...

متن کامل

Performance of a Radiation Portal Freight Monitor based on Integrated Germanium Detector Modules

Portal monitors, container scanners, and mobile search systems, constructed with high resolution germanium (HPGe) detectors, are currently being installed at locations world-wide. This reflects a general desire for improved performance and a reduction in the time to make a good decision in interdiction cases. An integrated gamma-ray spectrometer, incorporating a mechanically-cooled HPGe detecto...

متن کامل

An Evaluation of Ridge Extraction Methods for Portal Imaging

In this paper an existing ridge detector based on the Hessian tensor and a new one based on the structure tensor are evaluated for use in portal/simulator imaging. Tensor smoothing is introduced as a scaling parameter. By changing this scale (as opposed to the image scale) the detectors can be tuned to suppress spurious ridges without moving them. Desirable ridge detector properties for portal/...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Applied sciences

سال: 2022

ISSN: ['2076-3417']

DOI: https://doi.org/10.3390/app12189001