Performance evaluation of a second generation metaphase finder for chromosome-based radiation dosimetry.
نویسندگان
چکیده
منابع مشابه
Evaluation of dosimetry a performance parameter for a homemade farmer-type ionization chamber according to IEC60731
Introduction: Due to its simplicity, fast response and high reliability, ion chamber detectors are one of the most suitable dosimetry instruments for X and gamma rays. The dosimeter of photon beams, which used in radiotherapy centers, requires high accuracy and should pass requirements of IEC 60731 standards. About 80 percent of the IEC 60731 standard tests such as stabil...
متن کاملApplication of the premature chromosome condensation assay in simulated partial-body radiation exposures: evaluation of the use of an automated metaphase-finder.
The premature chromosome condensation (PCC) assay has been proposed as a useful and rapid end point for biological dosimetry following accidental high-dose radiation overexposures. A major benefit of the PCC assay is that it does not require cells to divide for evaluation of cytogenetic damage. The PCC assay was performed on isolated human peripheral lymphocytes exposed in vitro to doses from 1...
متن کاملConstruction of a dose – response curve by induction of premature chromosome condensation for biological dosimetry
Premature Chromosome Condensation (PCC) appears to have a possible utility for biological dosimetry purposes. The PCC technique may be adapted for cases of suspicion of overexposure where sampling is performed at least one day after an accident. For this purpose, human blood samples were exposed in vitro to 60Co up to 10 Gy and the PCC technique was performed immediately after irradiation. Anal...
متن کاملA new image analysis system for biological dosimetry by fluorescent in situ hybridization. Step 1: metaphase finder and automatic metaphase acquisition validation.
Because of the large number of cells to be analyzed in cases of overexposure to ionizing radiation, an automated imaging system is desirable for scoring both translocations and dicentrics. This system should include three essential steps: automatic metaphase finding, automatic image capture at high magnification, and, finally, optimized data analysis for aberration interpretation. We evaluated ...
متن کاملA CVH-based computational female pelvic phantom for radiation dosimetry simulation
Background: Accurate voxel phantom is needed for dosimetric simulation in radiation therapy for malignant tumors in female pelvic region. However, most of the existing voxel phantoms are constructed on the basis of Caucasian or non-Chinese population. Materials and Methods: A computational framework for constructing female pelvic voxel phantom for radiation dosimetry was performed base...