Performance Evaluation of a CO2 Refrigeration System Enhanced with a Dew Point Cooler
نویسندگان
چکیده
منابع مشابه
Advanced Analysis of Dew Point Control Unit of Hybrid Refrigeration Systems in Gas Refineries
In this paper, an advanced analysis of a novel hybrid compression-absorption refrigeration system (HCARS) for natural gas dew point control unit in a gas refinery is presented. This unit separates the heavy hydrocarbon molecules in the natural gas, which is traditionally carried out by natural gas cooling in a compression refrigeration cycle (CRS). The power input required for the refrigeration...
متن کاملPerformance Analysis of CO2/NH3 Cascade Refrigeration System Using ANNs
In this study, artificial neural networks (ANNs) have been used for performance analysis of a CO2/NH3 cascade refrigeration system using a data set, obtained from a thermodynamic model implemented in EES. Thermodynamic parameters of the system are estimated in terms of condensing temperature of ammonia, evaporating temperature of carbon dioxide, condensing temperature of carbon dioxide and temp...
متن کاملPerformance Evaluation of a Solar Adsorption Refrigeration System with a Wing Type Compound Parabolic Concentrator
Simulation study of a solar adsorption refrigeration system using a wing type compound parabolic concentrator (CPC) is presented. The system consists of the wing type collector set at optimum angles, adsorption bed, a condenser and a refrigerator. The wing type collector captures the solar energy efficiently in the morning and afternoon and provides the effective temperature for a longer period...
متن کاملSimulation and Validation of a R404A/CO2 Cascade Refrigeration System
The interest in natural refrigerants, such as carbon dioxide, has been growing in recent years due to the high direct global warming potential of common HFC refrigerants. Despite the environment-friendly characteristics of CO2 as a refrigerant, due to high heat rejection temperatures and transcritical operation, CO2 cannot match the high energy efficiency associated with current HFC technology....
متن کاملCoefficient of Performance Optimization of a Single Stage Thermoelectric Cooler
In thermoelectric coolers (TECs) applied external voltage potential is generated to a temperature difference based on the Peltier effect. Main and basic structure of TECs is in the form of single stage device. Due to the low efficiency, especially low coefficient of performance (COP) of thermoelectric coolers, optimal design of geometrical parameters of such devices is vital. For this purpose, ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Energies
سال: 2019
ISSN: 1996-1073
DOI: 10.3390/en12061079