Performance Characteristics of Hemolysis Index on Roche Cobas 8000 Automated Analyzers Including Correlation of Hemolysis Index With Free Hemoglobin Concentration in Plasma
نویسندگان
چکیده
منابع مشابه
Can the Roche hemolysis index be used for automated determination of cell-free hemoglobin? A comparison to photometric assays.
OBJECTIVES The aim of this study was to develop a novel method for automated quantification of cell-free hemoglobin (fHb) based on the HI (Roche Diagnostics). METHODS The novel fHb method based on the HI was correlated with fHb measured using the triple wavelength methods of both Harboe [fHb, g/L = (0.915 * HI + 2.634)/100] and Fairbanks et al. [fHb, g/L = (0.917 * HI + 2.131)/100]. fHb conce...
متن کاملassessment of the park- ang damage index for performance levels of rc moment resisting frames
چکیده هدف اصلی از طراحی لرزه ای تامین ایمنی جانی در هنگام وقوع زلزله و تعمیر پذیر بودن سازه خسارت دیده، پس از وقوع زلزله است. تجربه زلزله های اخیر نشان داده است که ساختمان های طراحی شده با آیین نامه های مبتنی بر نیرو از نظر محدود نمودن خسارت وارده بر سازه دقت لازم را ندارند. این امر سبب پیدایش نسل جدید آیین نامه های مبتنی بر عملکرد شده است. در این آیین نامه ها بر اساس تغییرشکل های غیرارتجاعی ...
15 صفحه اولBlood sampling and hemolysis affect concentration of plasma metabolites.
Two experiments were carried out to reveal and quantify plasma metabolites that are sensitive to hemolysis and animal stress due to the blood sampling procedure (vein puncture vs. catheter). In Exp. 1, 48 sows were fed 4 diets either once (0800 h) or twice daily (0800 h and 1500 h) in a crossover design and blood was collected after restraint via vein puncture 1, 4, 11, and 23 h after morning f...
متن کاملSpurious hemolysis does not influence the reliability of digoxin testing on Siemens RXL MAX and Roche Cobas e601.
Little information is available on the influence of spurious hemolysis on digoxin immunoassays. Seventeen consecutive, non-hemolyzed, sodium-heparin samples were divided in three aliquots. The first was immediately centrifuged and tested for hemolysis index (HI), as well as plasma digoxin on Siemens RXL MAX using the Siemens Dimension Flex and Roche Cobas e601 by electrochemiluminescent (ECLIA)...
متن کاملHemolytic index – A tool to measure hemolysis in vitro
Introduction: Hemolysis is the commonest causeof pre analytical error. Hemoglobin released interferes with analyte concentration chemically and optically.