Performance Characteristics of BGO Detectors for a Low Cost Preclinical PET Scanner

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance evaluation of an Inveon PET preclinical scanner.

We evaluated the performance of an Inveon preclinical PET scanner (Siemens Medical Solutions), the latest MicroPET system. Spatial resolution was measured with a glass capillary tube (0.26 mm inside diameter, 0.29 mm wall thickness) filled with (18)F solution. Transaxial and axial resolutions were measured with the source placed parallel and perpendicular to the axis of the scanner. The sensiti...

متن کامل

Performance characteristics of a whole-body PET scanner.

METHODS This study characterizes the performance of a newly developed whole-body PET scanner (Advance, General Electric Medical Systems, Milwaukee, WI). The scanner consists of 12,096 bismuth germinate crystals (4.0 mm transaxial by 8.1 mm axial by 30 mm radial) in 18 rings, giving 35 two-dimensional image planes through an axial field of view of 15.2 cm. The rings are separated by retractable ...

متن کامل

Implementation of quadratic dose protocol for 18F-FDG whole-body PET imaging using a BGO-based PET/CT scanner, GE Discovery ST

Introduction: The ability of quadratic dose protocol to maintain a good quality image for an overweight and obese patient is well reported. However, a practical approach to the implementation of this protocol in whole-body imaging in Malaysia is currently lacking. Hence, the aim of this study is to derive the quadratic dose formula that suits our PET system. Metho...

متن کامل

A prototype PET scanner with DOI-encoding detectors.

UNLABELLED Detectors with depth-encoding allow a PET scanner to simultaneously achieve high sensitivity and high spatial resolution. METHODS A prototype PET scanner, consisting of depth-encoding detectors constructed by dual-ended readout of lutetium oxyorthosilicate (LSO) arrays with 2 position-sensitive avalanche photodiodes (PSAPDs), was developed. The scanner comprised 2 detector plates, ...

متن کامل

Performance of a whole-body PET scanner using curve-plate NaI(Tl) detectors.

UNLABELLED A whole-body PET scanner, without interplane septa, has been designed to achieve high performance in clinical applications. The C-PET scanner, an advancement of the PENN PET scanners, is unique in the use of 6 curved NaI(Tl) detectors (2.54 cm thick). The scanner has a ring diameter of 90 cm, a patient port diameter of 56 cm, and an axial field of view of 25.6 cm. A (137)Cs point sou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Nuclear Science

سال: 2010

ISSN: 0018-9499,1558-1578

DOI: 10.1109/tns.2010.2046753