Articulated Arm Coordinate Measuring Machine Calibration by Laser Tracker Multilateration
A new procedure for the calibration of an articulated arm coordinate measuring machine (AACMM) is presented in this paper. First, a self-calibration algorithm of four laser trackers (LTs) is developed. The spatial localization of a retroreflector target, placed in different positions within the workspace, is determined by means of a geometric multilateration system constructed from the four LTs...
متن کاملLaser Tracker Calibration Using Coordinate Measuring Machine
This paper presents the achievement of a China NSFC project. A technique to calibrate laser tracker using CMM has been developed. A laser tracker with working range of 35m can be calibrated accurately and quickly using a CMM with working range of 1m. Studies have shown that angular errors are the key contributor to measuring errors of laser tracker. A device to measure angular errors of laser t...
متن کاملModelling and Calibration Technique of Laser Triangulation Sensors for Integration in Robot Arms and Articulated Arm Coordinate Measuring Machines
A technique for intrinsic and extrinsic calibration of a laser triangulation sensor (LTS) integrated in an articulated arm coordinate measuring machine (AACMM) is presented in this paper. After applying a novel approach to the AACMM kinematic parameter identification problem, by means of a single calibration gauge object, a one-step calibration method to obtain both intrinsic-laser plane, CCD s...
متن کاملKinematic calibration of a parallel robot using coordinate measuring machine
In the applications of parallel robots, kinematic calibration is required to eliminate the errors resulting from the manufacturing and assembly. In this paper, a new method for calibrating a parallel robot is proposed. An error model for kinematic calibration is constructed using differential geometry method. All leg length information and pose error are obtained based on measurement results co...
متن کاملPerformance Evaluation of Probing Systems in Data Capture for Kinematic Parameter Identification and Verification of Articulated Arm Coordinate Measuring Machines
This paper presents a comparison of different techniques to capture nominal data for its use in later verification and kinematic parameter identification procedures for articulated arm coordinate measuring machines (AACMM). By using four different probing systems (passive spherical probe, active spherical probe, self-centering passive probe and selfcentering active probe) the accuracy and rep...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Procedia Engineering
سال: 2013
ISSN: 1877-7058
DOI: 10.1016/j.proeng.2013.08.264