Performance Analysis of an Adsorption Refrigeration System Working on Activated Carbon/Methanol Pair Using Finned Tube Type Adsorber Bed
نویسندگان
چکیده
Adsorption refrigeration, being a unique and eco-friendly technology, has gained popularity over conventional refrigeration systems. The present study is aimed at developing an annular finned tube adsorber model which serves as thermal compressor in adsorption mathematical addressed numerically using finite difference discretization method explicit scheme was used for the solution. generalized been simulated activated carbon–methanol working pair. system optimum cycle time of 1800s. It found to have highest capacity 260.66 kJ/kg regeneration temperature 393 K evaporator 283 K. COP (Coefficient Performance) achieved by 0.3706 353 A SCP (Specific Cooling Power) 144.8 W/kg obtained
منابع مشابه
Performance Analysis of a Double-effect Adsorption Refrigeration Cycle with a Silica Gel/Water Working Pair
A numerical investigation of the double-effect adsorption refrigeration cycle is examined in this manuscript. The proposed cycle is based on the cascading adsorption cycle, where condensation heat that is produced in the top cycle is utilized as the driving heat source for the bottom cycle. The results show that the double-effect cycle produces a higher coefficient of performance (COP) as compa...
متن کاملTheoretical Study of Indirect Heating Temperature Swing Adsorption in an Adsorbent Coated Finned Tube Heat Exchanger
In this study, the performance of an adsorbent coated finned tube exchanger for carbon capture was investigated numerically. The results showed that this structure has a great potential for being applied as a medium for CO2 capture by rapid indirect thermal swing adsorption. By using this structure, the recovery of 96%, and purity of 98% were achieved with a simple cycle consisting of two steps...
متن کاملNumerical Studies on the Performance of Finned-Tube Heat Exchanger
Finned-tube heat exchangers are predominantly used in space conditioning systems, as well as other applications requiring heat exchange between two fluids. The design of finned-tube heat exchangers requires the selection of over a dozen design parameters by the designer such as tube pitch, tube diameter, tube thickness, etc... Finned-tube heat exchangers are common devices; however, their perfo...
متن کاملPerformance Evaluation of a Solar Adsorption Refrigeration System with a Wing Type Compound Parabolic Concentrator
Simulation study of a solar adsorption refrigeration system using a wing type compound parabolic concentrator (CPC) is presented. The system consists of the wing type collector set at optimum angles, adsorption bed, a condenser and a refrigerator. The wing type collector captures the solar energy efficiently in the morning and afternoon and provides the effective temperature for a longer period...
متن کاملPerformance Analysis of CO2/NH3 Cascade Refrigeration System Using ANNs
In this study, artificial neural networks (ANNs) have been used for performance analysis of a CO2/NH3 cascade refrigeration system using a data set, obtained from a thermodynamic model implemented in EES. Thermodynamic parameters of the system are estimated in terms of condensing temperature of ammonia, evaporating temperature of carbon dioxide, condensing temperature of carbon dioxide and temp...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Heat and Technology
سال: 2021
ISSN: ['0392-8764']
DOI: https://doi.org/10.18280/ijht.390433