Performance analysis of a R744 and R404A cascade refrigeration system with internal heat exchanger
نویسندگان
چکیده
منابع مشابه
Simulation and Validation of a R404A/CO2 Cascade Refrigeration System
The interest in natural refrigerants, such as carbon dioxide, has been growing in recent years due to the high direct global warming potential of common HFC refrigerants. Despite the environment-friendly characteristics of CO2 as a refrigerant, due to high heat rejection temperatures and transcritical operation, CO2 cannot match the high energy efficiency associated with current HFC technology....
متن کاملPerformance Investigation of Two Two-Stage Trans-Critical Carbon Dioxide Refrigeration Cycles Ejector and Internal Heat Exchanger
In the present work, the performances of improved two-stage multi inter-cooler trans- critical carbon dioxide (CO2) refrigeration cycles with ejector and internal heat exchanger have been examined. In the new improved cycles, an internal heat exchanger is append to the cycles. Also, second inter-cooler in improved cycles, cooled with the refrigeration of the cycle, so that in first c...
متن کاملNumerical Simulation of Heat Exchanger Area of R410A-R23 and R404A-R508B Cascade Refrigeration System at Various Evaporating and Condensing Temperature
Capacity and efficiency of any refrigerating system diminish rapidly as the difference between the evaporating and condensing temperature is increased by reduction in the evaporator temperature. The single stage vapour compression refrigeration system is limited to an evaporator temperature of -40 C. Below temperature of -40 C the either cascade refrigeration system or multi stage vapour compre...
متن کاملDynamic Modeling of a Refrigeration System with an Internal Heat Exchanger and Dual Evaporators through Exergoeconomic Analysis
In this study exergy and exergoeconomic analyses of a refrigeration system with two evaporators and an internal heat exchanger were performed. The analysis of the whole system included various thermodynamics parameters such as sustainability index, exergetic improvement potential, ratio of the thermodynamic losses(energetic and exergetic losses) to the capital cost, relative irreversibility for...
متن کاملNumerical Simulation of R410a-R23 and R404A-R508B Cascade Refrigeration System
Capacity and efficiency of any refrigerating system diminish rapidly as the difference between the evaporating and condensing temperature is increased by a reduction in the evaporator temperature. The single stage vapour compression refrigeration system using various refrigerants are limited to an evaporator temperature of -40 0C. Below temperature of -40 0C the either cascade refrigeration sys...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of the Korea Society For Power System Engineering
سال: 2012
ISSN: 1226-7813
DOI: 10.9726/kspse.2012.16.1.038