Percutaneous transcolonic puncture of retained Foley balloon catheter.

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Percutaneous transcolonic puncture of retained Foley balloon catheter.

A case of large bowel obstruction complicated by a retained intracolonic Foley balloon catheter is reported, and the minimally invasive technique for removal is described.

متن کامل

Extraluminal location of a Foley catheter balloon.

Hong Kong Med J ⎥ Volume 23 Number 2 ⎥ April 2017 ⎥ www.hkmj.org Indwelling urinary catheters are generally safe but may be associated with complications. Although intraperitoneal or extraperitoneal perforation is rare, the condition can be life-threatening.1 Abdominopelvic computed tomography (CT) is commonly performed in hospitalised patients. In many cases the urinary bladder is catheterised...

متن کامل

Foley catheter balloon endometrial ablation: successful treatment of three cases.

Endometrial ablation is one of the most effective methods for treatment of dysfunctional uterine bleeding (DUB). Balloon devices with circulating hot water inside or electrodes on the outer surface and radiofrequency-induced thermal destructors are the most recently introduced available tools for endometrial ablation. All of these methods are effective and simple but expensive technologies. The...

متن کامل

Management of the Retained Percutaneous Nephrostomy Catheter

Percutaneous nephrolithotomy is a widely accepted treatment for urinary calculi, but it is not without complications. We present the case of a 76-year-old male with a retained council tip catheter after percutaneous nephrolithotomy. Fluoroscopic guidance was used to perform percutaneous puncture of the catheter balloon, and the catheter was removed without complication. Advantages of various ne...

متن کامل

Transcolonic Migration of Retained Epicardial Pacing Wires

Temporary epicardial pacing wires are associated with rare complications. Most of these occur in the chest. Even rarer are complications that occur within the abdomen. We report a case of migrating epicardial pacing wires entering the abdomen and penetrating the transverse colon found incidentally on colonoscopy in an asymptomatic patient.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Postgraduate Medical Journal

سال: 1989

ISSN: 0032-5473

DOI: 10.1136/pgmj.65.769.845