Percutaneous intravenous insertion of an ordinary double-lumen catheter.
نویسندگان
چکیده
منابع مشابه
Variables influencing intravenous catheter insertion difficulty and failure: an analysis of 339 intravenous catheter insertions.
BACKGROUND Inserting an intravenous catheter (IV) is one of the most frequently performed invasive procedures by nurses. Little research has been conducted on ways to reduce the difficulty and failure, and enhance the ease and success, of IV insertion. We conducted this study to determine variables associated with IV insertion difficulty, failure, and success, and to learn special techniques nu...
متن کاملUnusual clot formation following insertion of central double lumen catheter for hemodialysis.
BACKGROUND We report a case of a patient with chronic renal failure (CRF) due to fibrillary glomerulonephritis, who was admitted to our Hospital with fever accompanied by chills, of two days duration. Due to aggravation of his CRF, accompanied by severe metabolic acidosis, an internal jugular double lumen central vein catheter was inserted, through which he was hemodialyzed. METHODS Blood cul...
متن کاملShould a Double-Lumen Catheter be withdrawn?
Haemodialysis needs a credible and recurrent access to the systemic circulation which can be accomplished by way of central vein catheterization. We report the case of bleeding after withdrawal of the double lumen catheter. A 36-year-old woman who was a known case of end-stage renal disease referred to a dialysis center because of her arteriovenous fistula malfunction. A double-lumen catheter w...
متن کاملDouble-Lumen Flotation Catheter for Use
A DOUBLE-LUMEN flotation catheter* is now used regularly in myocardial infarction research units to obtain right heart pressures in acutely ill patients. It has proven a safe and reliable method of obtaining right heart pressures without fluoroscopy. The technique is simple: A 5-French double-lumen catheter with a small inflatable rubber balloon just proximal to the tip is inserted into a perip...
متن کاملDouble lumen endotracheal tube for percutaneous tracheostomy?
BACKGROUND Percutaneous dilational tracheostomy is normally a bronchoscope-guided procedure. The insertion of a bronchoscope into an endotracheal tube (ETT) affects resistance, flow, and alveolar pressure. To improve airway management and ventilation during percutaneous tracheostomy, we developed a double lumen endotracheal tube (DLET). The aim of this in vitro study was to compare the linear c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Heart
سال: 1966