Peptide Nanotube Encapsulated Enzyme Biosensor for Vapor Phase Detection of Malathion, an Organophosphorus Compound
نویسندگان
چکیده
منابع مشابه
Development of Peptide Nanotube-modified Biosensors for Gas-phase Organophosphate Detection Thesis
Vapor-phase detection of the model organophosphate (OP) malathion was achieved using enzymes encapsulated in peptide nanotubes and attached to gold screen printed electrodes. The peptide nanotubes had horseradish peroxidase (HRP) encapsulated inside and both acetylthiocholine (ASCh) and acetylcholinesterase (AChE) coated on the outside. ASCh hydrolysis, which produces thiocholine, was catalyzed...
متن کاملPoly(ethylene glycol) hydrogel-encapsulated fluorophore-enzyme conjugates for direct detection of organophosphorus neurotoxins.
A simple approach is described for preparing poly-(ethylene glycol) hydrogel materials with encapsulated seminapthofluorescein (SNAFL)-organophosphorus hydrolase enzyme conjugates. Direct determination of enzyme-catalyzed neurotoxin hydrolysis is provided by the self-referencing, pH-sensitive dye SNAFL-1, whose emission spectrum changes at lambda = 550 in response to pH. Using spectrofluorimetr...
متن کاملPreparation of Electrochemical Biosensor for Detection of Organophosphorus Pesticides
Polyvinyl chloride (PVC) can be used to develop reaction beaker which acts as electrochemical cell for the measurement of OP pesticides. Being chemically inert, corrosion resistant, and easy in molding to various shapes and size, PVC can be used for the immobilization of enzyme. Organophosphorus hydrolase was immobilized covalently onto the chemically activated inner surface of PVC beaker by us...
متن کاملDual amperometric–potentiometric biosensor detection system for monitoring organophosphorus neurotoxins
A dual-transducer flow-injection biosensor detection system for monitoring organophosphorus (OP) neurotoxins is described. Such simultaneous use of different physical transducers in connection to the same (organophosphorous hydrolase (OPH)) enzyme enhances the information content and provides discrimination between various subclasses of OP compounds. While the potentiometric biosensor responds ...
متن کاملPeptide-coated nanotube-based biosensor for the detection of disease-specific autoantibodies in human serum.
We demonstrate a label-free peptide-coated carbon nanotube-based immunosensor for the direct assay of human serum. A rheumatoid arthritis (RA)-specific (cyclic citrulline-containing) peptide, was immobilized to functionalized single-walled carbon nanotubes deposited on a quartz crystal microbalance (QCM) sensing crystal. Serum from RA patients was used to probe these nanotube-based sensors, and...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Sensors
سال: 2019
ISSN: 1424-8220
DOI: 10.3390/s19183856