Pencil Beam Algorithms Are Unsuitable for Proton Dose Calculations in Lung
نویسندگان
چکیده
منابع مشابه
A GPU-Based Pencil Beam Algorithm for Dose Calculations in Proton Radiation Therapy
Recent developments in radiation therapy have been focused on applications of charged particles, especially—protons. Proton therapy can allow higher dose conformality compared to conventional radiation therapy. Dose calculations have an integral role in the successful application of proton therapy. Over the years several dose calculation methods have been proposed in proton therapy. A common ch...
متن کاملEvaluating Performance of Algorithms in Lung IMRT: A Comparison of Monte Carlo, Pencil Beam, Superposition, Fast Superposition and Convolution Algorithms
Background: Inclusion of inhomogeneity corrections in intensity modulated small fields always makes conformal irradiation of lung tumor very complicated in accurate dose delivery.Objective: In the present study, the performance of five algorithms via Monte Carlo, Pencil Beam, Convolution, Fast Superposition and Superposition were evaluated in lung cancer Intensity Modulated Radiotherapy plannin...
متن کاملFast Pencil Beam Dose Calculation for Proton Therapy Using a Double-Gaussian Beam Model
The highly conformal dose distributions produced by scanned proton pencil beams (PBs) are more sensitive to motion and anatomical changes than those produced by conventional radiotherapy. The ability to calculate the dose in real-time as it is being delivered would enable, for example, online dose monitoring, and is therefore highly desirable. We have previously described an implementation of a...
متن کاملGolden beam data for proton pencil-beam scanning.
Proton, as well as other ion, beams applied by electro-magnetic deflection in pencil-beam scanning (PBS) are minimally perturbed and thus can be quantified a priori by their fundamental interactions in a medium. This a priori quantification permits an optimal reduction of characterizing measurements on a particular PBS delivery system. The combination of a priori quantification and measurements...
متن کاملPoint dose calculations using an analytical pencil beam kernel for IMRT plan checking.
A method to verify the monitor units for a treatment plan is to calculate point doses, possibly at the isocentre, by using a simple calculation method. This verification is recommended to find mistakes in the treatment plan. Treatment plans for intensity modulated radiation therapy are no exception. The method should employ a simple physical model and a dose calculation algorithm, which is diff...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: International Journal of Radiation Oncology*Biology*Physics
سال: 2017
ISSN: 0360-3016
DOI: 10.1016/j.ijrobp.2017.06.003