Peering inside printed explosives using X-ray radiography
نویسندگان
چکیده
Flash X-ray radiography provides insights into additively manufactured high explosives and the complex wave interactions that can result.
منابع مشابه
Peering inside the proton
This contribution, a personal recollection by the author, is part of a special issue CERN’s accelerators, experiments and international integration 1959–2009. Guest Editor: Herwig Schopper [Schopper, Herwig. 2011. Editorial. Eur. Phys. J. H 36: 437]. What I am going to describe is the birth of the quark model as a viable, experimentally confirmed description of the structure of hadrons. The qua...
متن کاملPeering deeply inside the branch
The actin-related protein 2/3 (Arp2/3) story has captivated the cytoskeleton community for over a decade. Not only does this complex nucleate new actin filaments, but it also anchors them into a dendritic meshwork that is used in many cellular contexts such as lamellipodial protrusion, endosome rocketing, and the movement of pathogens. One key piece of this puzzle that has been missing is a det...
متن کاملX-ray detectors for digital radiography.
Digital radiography offers the potential of improved image quality as well as providing opportunities for advances in medical image management, computer-aided diagnosis and teleradiology. Image quality is intimately linked to the precise and accurate acquisition of information from the x-ray beam transmitted by the patient, i.e. to the performance of the x-ray detector. Detectors for digital ra...
متن کاملPeering Inside Peer Review with Bayesian Models
Instructors and students would benefit more from computersupported peer review, if instructors received information on how well students have understood the conceptual issues underlying the writing assignment. Our aim is to provide instructors with an evaluation of both the students and the criteria that students used to assess each other. Here we develop and evaluate several hierarchical Bayes...
متن کاملPatient effective dose evaluation for chest X-ray examination in three digital radiography centers
Background: The radiation doses resulting from diagnostic X-ray examinations are routinely measured in terms of entrance surface dose (ESD) and effective dose (ED). In this study, for the purpose of radiation protection, the radiation doses received from Digital chest X-ray examination were evaluated in terms of ESD and ED. Material and Methods: The ED was calculated by using the MCNP ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Scilight
سال: 2023
ISSN: ['2572-7907']
DOI: https://doi.org/10.1063/10.0019617