Pediatric cardiac toxicity associated with fentanyl ingestion

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Pediatric Case of Cardiac Toxicity Associated with Illicit Fentanyl Ingestion

Context: In North America, opioid-related deaths are on the rise. We report a case of pediatric cardiac toxicity likely related to illicit fentanyl ingestion. Case Details: A 14-year-old maleingested half of an unknown illicit pill. Two hours post ingestion, the patient experienced loss of consciousness, hypotension, cyanosis and diaphoresis. Initial labs revealed elevations in lactate and high...

متن کامل

Cardiovascular toxicity associated with yew leaf ingestion.

Multiform ventricular tachycardia and self-terminating ventricular fibrillation developed in a 16 year old girl who had deliberately eaten yew tree leaves.

متن کامل

Anticholinergic toxicity associated with lupin seed ingestion: case report.

We describe a case of acute poisoning in a 51-year-old female patient who presented to the Emergency Department with weakness, anxiety, dry mouth, bilateral mydriasis and lid drop. In differential diagnosis, botulism, Guillain-Barré syndrome and myasthenia gravis were considered, as well as cerebral haematoma because of a cranial injury a week before. Symptoms, which resolved within 12 h withou...

متن کامل

PEDIATRIC CARDIOLOGY Complications Associated With Pediatric Cardiac Catheterization

Objectives. The aim of this study was to determine the relative risks of pediatric diagnostic, interventional and electrophysiologic catheterizations. Background. The role of the pediatric catheterization laboratory has evolved in the last decade as a therapeutic modality, although remaining an important tool for anatomic and hemodynamic diagnosis. Methods. A study of 4,952 consecutive pediatri...

متن کامل

Erosive Pressure Dermatitis Associated with Cardiac Pacemaker

Erosive dermatitis is a skin reaction associated with implantable cardiac devices (ie, pacemakers and cardioverter defibrillators). We report a 65-year-old man with a history of several cerebrovascular attacks who developed an erythematous crusted erosive patch over the pacemaker site after implantation of two subsequent pacemakers. We suggest that physical irritation may be a trigger factor fo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Toxicology Communications

سال: 2018

ISSN: 2473-4306

DOI: 10.1080/24734306.2018.1459108