Peak Expiratory Flow in Normal Subjects

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Peak Expiratory Flow Rate in Healthy Children from Tehran

Background: Measuring peak expiratory flow rate has been suggested as an important tool in asthma management by all international guidelines.  Objective: Studies on various populations have shown considerable variations in normal values of peak expiratory flow rate. Since reference standards for Iranian children are not available, the present study was performed to establish these standards. Me...

متن کامل

Comparison of circadian variations using FEV1 and peak expiratory flow rates among normal and asthmatic subjects.

BACKGROUND Most studies that describe circadian variations in asthma have used maximum rate of peak expiratory flow (PEF) rather than forced expiratory volume in one second (FEV1) to assess airway calibre. This study was designed to assess circadian variations in PEF and FEV1 measured simultaneously and to compare variations in these measurements in normal and asthmatic subjects in a stable cli...

متن کامل

Normal measurement of peak expiratory Flow rate in the high school children in Babol, north of Iran

Background: Peak Expiratory Flow Rate (PEFR) is recommended as a tool for control of asthma. The purpose of this study was to determine the normal value of PEFR in the healthy high school children in Babol, Iran. Methods: This study was conducted on 470 healthy high school children (285 girls, 185 boys with the age between 14-18 years). For the determination of PEFR we used Mini Wright Peak Flo...

متن کامل

Peak flowmeter resistance decreases peak expiratory flow in subjects with COPD.

Previous studies have shown that the added resistance of a mini-Wright peak expiratory flow (PEF) meter reduced PEF by approximately 8% in normal subjects because of gas compression reducing thoracic gas volume at PEF and thus driving elastic recoil pressure. We undertook a body plethysmographic study in 15 patients with chronic obstructive pulmonary disease (COPD), age 65.9 +/- 6.3 yr (mean +/...

متن کامل

Peak expiratory flow at altitude.

The mini Wright peak flow meter is a useful, portable instrument for field studies but being sensitive to air density will under-read at altitude. True peak expiratory flow will increase at altitude, however, because of the decreased air density, given that dynamic resistance is unchanged. The effect of simulated altitude on peak expiratory flow (PEF) was determined in six subjects with both th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: BMJ

سال: 1973

ISSN: 0959-8138,1468-5833

DOI: 10.1136/bmj.3.5874.282