Peak Detector Effect in Low-Dropout Regulators
نویسندگان
چکیده
منابع مشابه
Voltage References and Low Dropout Linear Regulators
Reference circuits and linear regulators actually have much in common. In fact, the latter could be functionally described as a reference circuit, but with greater current (or power) output. Accordingly, almost all of the specifications of the two circuit types have great commonality (even though the performance of references is usually tighter with regard to drift, accuracy, etc.). This chapte...
متن کاملEvaluation and Characterization of Silicon MESFETs in Low Dropout Regulators
i ABSTRACT The partially-depleted (PD) silicon Metal Semiconductor Field Effect Transistor (MESFET) is becoming more and more attractive for analog and RF applications due to its high breakdown voltage. Compared to conventional CMOS high voltage transistors, the silicon MESFET can be fabricated in commercial standard Silicon-on-Insulator (SOI) CMOS foundries without any change to the process. T...
متن کاملA CMOS Voltage Reference Based on Weighted VGS for CMOS Low-Dropout Linear Regulators
A CMOS voltage reference, which is based on the weighted difference of the gate–source voltages of an NMOST and a PMOST operating in saturation region, is presented. The voltage reference is designed for CMOS low-dropout linear regulators and has been implemented in a standard 0.6m CMOS technology ( 0 9 V at 0 C). The occupied chip area is 0.055 mm. The minimum supply voltage is 1.4 V, and the ...
متن کاملLow Power and Low Latency Phase-Frequency Detector in Quantum-Dot Cellular Automata Nanotechnology
Nowadays, one of the most important blocks in telecommunication circuits is the frequency synthesizer and the frequency multipliers. Phase-frequency detectors are the inseparable parts of these circuits. In this paper, it has been attempted to design two new structures for phase-frequency detectors in QCA nanotechnology. The proposed structures have the capability of detecting the phase ...
متن کاملAdvanced Jindalee Tracker : Enhanced Peak Detector
This paper presents an analysis of the Jindalee Stage B Peak Detector and highlights a number of deficiencies. Solutions are proposed for these deficiencies and the improvements gained from their implementation are measured. These solutions overcome clustering about the data sample points. In addition, enhancements are made in the areas of: adaptive thresholding to maintain a constant false ala...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: IEEE Transactions on Nuclear Science
سال: 2013
ISSN: 0018-9499,1558-1578
DOI: 10.1109/tns.2012.2232305