PD knowledge rules for insulation condition assessment of distribution power cables

نویسندگان
چکیده

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Condition Monitoring of Power Cables

A National Grid funded research project at Southampton has investigated possible methodologies for data acquisition, transmission and processing that will facilitate on-line continuous monitoring of partial discharges in high voltage polymeric cable systems. A method that only uses passive components at the measuring points has been developed and is outlined in this paper. More recent work, fun...

متن کامل

The Application of Partial Discharge Detection for the condition assessment of XLPE Power Cables

Partial discharge (PD) detection is an important means in the condition-based maintenance of high voltage apparatus including crosslinked polyethylene (XLPE) power cables. In this contribution, we introduce the recent work in Shanghai municipal electric power company on the condition-based maintenance of XLPE power cables. As to how to carry out the PD detection in different circumstances, thre...

متن کامل

Grey Relational Analysis for Insulation Condition Assessment of Power Transformers Based Upon Conventional Dielectric Response Measurement

Conventional dielectric response measurement techniques, for instance, recovery voltage measurement (RVM), frequency domain spectroscopy (FDS) and polarization–depolarization current (PDC) are effective nondestructive insulation monitoring techniques for oil-impregnated power transformers. Previous studies have focused mainly on some single type of dielectric measurement method. However, the co...

متن کامل

Automated Ultrasonic Diagnosis for Condition Assessment of Electrical Insulation Systems

In electrical power engineering equipment like cables, transformers and switchgears high voltages occur which have to be isolated in a safe and reliable way. Thus the used insulation systems are very sensitive parts of such components, especially regarding the long required lifetime of more than 30 years. Especially for insulation systems made up of solid materials (resins, elastomers, thermopl...

متن کامل

a study of relationship between knowledge sharing and organizational agility among personnel in esfahan power electric distribution company

پژوهش حاضر به بررسی رابطه بین تسهیم دانش و چابکی سازمانی در شرکت توزیع برق استان اصفهان پرداخته است . ابزار سنجش در این پژوهش پرسشنامه می باشد . به منظور سنجش متغیر تسهیم دانش از پرسشنامه وانگ و وانگ و جهت سنجش چابکی سازمانی از پرسشنامه چاربونیر استفاده شده است . هدف پژوهش حاضر تحلیل رابطه میان تسهیم دانش و چابکی سازمانی از دید کارکنان شرکت توزیع برق استان اصفهان می باشد . جامعه آماری این پژوه...

15 صفحه اول

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: IEEE Transactions on Dielectrics and Electrical Insulation

سال: 2005

ISSN: 1070-9878

DOI: 10.1109/tdei.2005.1430393