Patient–prosthesis mismatch after mitral valve replacement: complex enigma with more than one solution

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Right sided heart evaluation after successful mitral valve replacement.

Introduction: It is well-documented that right-sided heart dysfunction and significant tricuspid valve regurgitation (TVR) have adverse effects on patient outcomes after left-sided heart valve surgery. Therefore, the evaluation of right ventriclular (RV) function and TR severity in patients who had undergone mitral valve replacement (MVR), associated with/without concomitant su...

متن کامل

Performance After Mitral Valve Replacement

To determine how survival and clinical status were related to left ventricular (LV) size and systolic function after mitral valve replacement, 104 patients (48 mitral regurgitation [MR], 33 mitral stenosis [MS], and 23 MS/MR) with isolated mitral valve replacement were evaluated before and after surgery. Preoperative hemodynamic abnormalities by cardiac catheterization were improved 6 months af...

متن کامل

Impact of valve prosthesis-patient mismatch on pulmonary arterial pressure after mitral valve replacement.

OBJECTIVES We sought to determine the impact of valve prosthesis-patient mismatch (PPM) on pulmonary arterial (PA) pressure after mitral valve replacement (MVR). BACKGROUND Pulmonary arterial hypertension is a serious complication of mitral valve disease, and it is a major risk factor for poor outcome after MVR. We hypothesized that valve PPM might be a determinant of PA hypertension after MV...

متن کامل

Prosthesis-patient mismatch after mitral valve replacement stratified by referred and measured effective valve area.

OBJECTIVE The aim of this study was to determine the impact of patient-prosthesis mismatch (PPM) after mitral valve replacement (MVR) on the late clinical outcome, evaluated from the referred value and measured mitral valve area in the echocardiograph. PATIENTS AND METHOD The records of 212 patients who underwent MVR between 1995 and 2008 at Funabashi Municipal Medical Center, Japan were stud...

متن کامل

Impact of prosthesis-patient mismatch after mitral valve replacement in rheumatic population: Does mitral position prosthesis-patient mismatch really exist?

BACKGROUND Prosthesis-patient mismatch (PPM) is characterised by the effects of inadequate prosthesis size relative to body surface area (BSA).The purpose of this study was to determine the impact of PPM on late clinical outcomes after mitral valve replacement (MVR) in rheumatic population. METHODS From 2000 to 2013, a total of 445 patients (mean age 54.2 ± 11.7 years) underwent isolated MVR ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: European Journal of Cardio-Thoracic Surgery

سال: 2018

ISSN: 1010-7940,1873-734X

DOI: 10.1093/ejcts/ezy163