Patient‐Perceived Differences Between Constant Current and Constant Voltage Spinal Cord Stimulation Systems

نویسندگان
چکیده

برای دانلود باید عضویت طلایی داشته باشید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of patient preference for constant voltage and constant current spinal cord stimulation.

OBJECTIVES   Spinal cord stimulation devices control energy by generating either constant voltage (CV) pulses or constant current (CC) pulses. This study aimed to investigate: 1) whether patients feel differences between CV and CC stimulation; 2) if patients prefer CV or CC stimulation. METHODS   Fourteen patients blinded to the type of pulse generation received 20 randomized pairs of 15-sec ...

متن کامل

A constant-voltage and constant-current stimulus isolation unit.

When action potentials from a stimulated biological preparation are recorded i t is essential to isolate the stimulus resistively and capacitively from the ground in order to minimize stimulation artifacts. Such isolation can be achieved by using a transformer of special low-capacitance construction in the output of a stimulus generator (Donaldson 1958). The most widely used arrangement for the...

متن کامل

Constant Current versus Constant Voltage Subthalamic Nucleus Deep Brain Stimulation in Parkinson's Disease.

Background: Subthalamic nucleus (STN) deep brain stimulation (DBS) is an established therapy for advanced Parkinson's disease (PD). Motor efficacy and safety have been established for constant voltage (CV) devices and more recently for constant current (CC) devices. CC devices adjust output voltage to provide CC stimulation irrespective of impedance fluctuation, while the current applied by CV ...

متن کامل

Measurement of electrogenic-pump current in Aplysia neurones with constant-current and constant-voltage techniques.

1. The responses of the abdominal and pleural giant cells to warming and cooling were studied using constant-current and constant-voltage techniques. 2. The potential change upon warming from about 7 degrees C to 22 degrees C was reversed by application of maintained inward current. The reversal potential was -77 +/- 12 mV. 3. The membrane conductance increased with warming, but was not affecte...

متن کامل

Energy consumption analysis of constant voltage and constant current operations in capacitive deionization

a b s t r a c t a r t i c l e i n f o Article history: Received 2 June 2016 Received in revised form 9 August 2016 Accepted 15 September 2016 Available online xxxx We report our studies to compare energy consumption of a CDI cell in constant voltage (CV) and constant current (CC) operations, with a focus on understanding the underlying physics of consumption patterns. The comparison is conducte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

ژورنال

عنوان ژورنال: Neuromodulation: Technology at the Neural Interface

سال: 2013

ISSN: 1094-7159,1525-1403

DOI: 10.1111/ner.12085