PATIENT TRIAL EVALUATION OF A PERFORATED, PIN-LOCK PROSTHETIC LINER FOR SWEAT MANAGEMENT
نویسندگان
چکیده
منابع مشابه
Quantification of prosthetic outcomes: elastomeric gel liner with locking pin suspension versus polyethylene foam liner with neoprene sleeve suspension.
For this randomized crossover trial, we compared two common transtibial socket suspension systems: the Alpha liner with distal locking pin and the Pe-Lite liner with neoprene suspension sleeve. Our original hypotheses asserted that increased ambulatory activity, wear time, comfort, and satisfaction would be found with the elastomeric suspension system. Thirteen subjects completed the study. Fol...
متن کاملManagement of Seafarers in Liner Shipping Industry
The use of Human Resource Management (HRM) practices in the form of ‘bundles’ and in integration with the business strategy of the organisation have been emphasised throughout the HRM literature. These are called the horizontal integration and vertical integration respectively. This article aim at examining the use of these practices in liner shipping industry in which human element plays a vi...
متن کاملDesign and Evaluation of a Magnetorheological Damper Based Prosthetic Knee
In this work, a magnetorheological (MR) damper based above-knee prosthesis is design and evaluated based on its performance in swing phase and in stance phase. Initially, a dynamic system model for swing phase of a prosthetic leg incorporating a single-axis knee with ideal MR damper was built. The dynamic properties of the damper are represented with Bingham parametric model. From Bingham model...
متن کاملA clinical comparison between two common transtibial Prosthetic suspension systems
Introduction: Proper fitting of the stump inside the socket and appropriate selection of prosthetic suspension have positive effects on amputees’ satisfaction and could decrease gait deviation, skin problems, and stump atrophy. The suction sockets are commonly prescribed for transtibial amputees to have better suspension compared to the Pin and lock systems. The Seal-In® X5 (suction system) is ...
متن کاملA trial design for evaluation of empiric programming of implantable cardioverter defibrillators to improve patient management
The delivery of implantable cardioverter defibrillator (ICD) therapy is sophisticated and requires the programming of over 100 settings. Physicians tailor these settings with the intention of optimizing ICD therapeutic efficacy, but the usefulness of this approach has not been studied and is unknown. Empiric programming of settings such as anti-tachycardia pacing (ATP) has been demonstrated to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Canadian Prosthetics & Orthotics Journal
سال: 2018