Patient acceptability of the Tecnis® multifocal intraocular lens
نویسندگان
چکیده
منابع مشابه
Patient acceptability of the Tecnis® multifocal intraocular lens
Cataract surgery has evolved. The goal of the surgeon includes both restoration of vision and refinement of vision. Patients' desire for spectacle independence has driven the market for presbyopia-correcting cataract surgery and development of novel intraocular lens (IOL) designs. The Tecnis(®) Multifocal Intraocular Lens incorporates an aspheric, modified anterior prolate IOL with a diffractiv...
متن کاملRefractive lens exchange with an array multifocal intraocular lens.
PURPOSE To prospectively evaluate safety, efficacy, predictability, stability, complications, and patient satisfaction after refractive lens exchange (clear lens extraction) followed by posterior chamber implantation of a multifocal intraocular lens (IOL). METHODS Fifty eyes of 25 patients (mean age 51 years, range 44 to 62 years) with preoperative spherical equivalent refraction between -15....
متن کاملOptical bench performance of a novel trifocal intraocular lens compared with a multifocal intraocular lens
PURPOSE The purpose of this study is to compare the optical characteristics of the novel PanOptix presbyopia-correcting trifocal intraocular lens (IOL) and the multifocal ReSTOR +3.0 D IOL, through in vitro bench investigations. METHODS The optical characteristics of AcrySof(®) IQ PanOptix™ (PanOptix) and AcrySof(®) IQ ReSTOR +3.0 D (ReSTOR +3.0 D) IOLs were evaluated by through-focus Badal i...
متن کاملThe ReZoom multifocal intraocular lens: 2-year follow-up.
PURPOSE To evaluate distance, intermediate, and near visual acuity and patient satisfaction over a period of 2 years after implantation of the ReZoom multifocal intraocular lens. METHODS Fifty-five eyes of 35 cataract patients were included in this retrospective study. Only patients with a preoperative photopic pupillary diameter superior to 3 mm were included. Monocular visual acuities and v...
متن کاملPiggyback intraocular lens implantation to correct pseudophakic refractive error after segmental multifocal intraocular lens implantation.
PURPOSE To evaluate refractive and visual outcomes of secondary piggyback intraocular lens implantation in patients diagnosed as having residual ametropia following segmental multifocal lens implantation. METHODS Data of 80 pseudophakic eyes with ametropia that underwent Sulcoflex aspheric 653L intraocular lens implantation (Rayner Intraocular Lenses Ltd., East Sussex, United Kingdom) to corr...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Clinical Ophthalmology
سال: 2011
ISSN: 1177-5483
DOI: 10.2147/opth.s11126