Patent Ductus Arteriosus Device Closure with AMPLATZER Duct Occluder-II in a Low Birth Weight Preterm Neonate- First Experience in Pakistan
نویسندگان
چکیده
We report a successful closure of large patent ductus arteriosus (PDA) in low-birth weight preterm neonate using an ADO IIdevice for the first time AFIC/NIHD Rawalpindi. A hemodynamically significant PDA carries anincreased risk morbidity, including chronic lung disease, necrotizing enterocolitis and renal impairment. After failure ofmedical therapy, successful, timely safe transcatheter appropriate equipment is milestone inmanaging neonates.
منابع مشابه
Transcatheter closure of large sized patent ductus arteriosus using the amplatzer duct occluder device.
OBJECTIVE To assess the results of anterograde transcatheter closure of a large sized patent ductus arteriosus using the Amplatzer Duct Occluder (ADO) device. STUDY DESIGN A case series. PLACE AND DURATION OF STUDY Department of Cardiology, Armed Forces Institute of Cardiology and National Institute of Heart Diseases, Rawalpindi, from January 2005 to December 2007. METHODOLOGY All patient...
متن کاملlong-term follow-up of patent ductus arteriosus closure with the amplatzer duct occluder in children
background: t ranscatheter closure of patent ductus arteriosus (pda) has become an alternative treatment to surgery. we evaluated the long-term results of the transcatheter closure of pda with the amplatzer duct occluder (ado) in children. methods: between may 2004 and october 2012, 138 children with pda (43 males and 95 females) underwent transcatheter pda closure. clinical, electrocardiograph...
متن کاملClosure of the patent ductus arteriosus with the new duct occluder II additional sizes device.
OBJECTIVE The objective of this study was to evaluate the technical feasibility, safety, and efficacy of the new device Amplatzer duct occluder II additional sizes (ADO II AS) for closure of patent ductus arteriosus (PDA). BACKGROUND Transcatheter device closure is the standard care for PDA. Currently available technology is not designed for closure of small PDA in young children. METHODS F...
متن کاملLong-Term Results of Transcatheter Closure of Patent Ductus Arteriosus in Infants Using Amplatzer Duct Occluder
OBJECTIVE Patent ductus arteriosus (PDA) is one of the most frequently seen congenital heart diseases. Its closure is recommended because of the risk of infective endocardis, as well as morbidity and mortality in the long. The aim of this study was to assess the long term results of the transcatheter closure of PDA in infants using amplatzer duct occlude (ADO). METHODS From May 2004 to Septem...
متن کاملTranscatheter closure of the patent ductus arteriosus using an Amplatzer duct occluder in adults.
Patent ductus arteriosus (PDA) is a congenital heart disease that frequently escapes detection until the patient reaches adulthood. Percutaneous closure of the PDA has been established as a safe alternative to surgery, the Amplatzer duct occluder (ADO) is a new device that has been recently reported in paediatric patients. Our initial experience with an of ADO in an adult population appears to ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Pakistan Armed Forces Medical Journal
سال: 2023
ISSN: ['2411-8842', '0030-9648']
DOI: https://doi.org/10.51253/pafmj.v73i2.7597