Patch-Probe Excitation for Ultrahigh Magnetic Field Wide-Bore MRI
نویسندگان
چکیده
منابع مشابه
Ultra-wide bore 900 MHz high-resolution NMR at the National High Magnetic Field Laboratory.
Access to an ultra-wide bore (105 mm) 21.1 T magnet makes possible numerous advances in NMR spectroscopy and MR imaging, as well as novel applications. This magnet was developed, designed, manufactured and tested at the National High Magnetic Field Laboratory and on July 21, 2004 it was energized to 21.1 T. Commercial and unique homebuilt probes, along with a standard commercial NMR console hav...
متن کاملUltrahigh field magnetic resonance imaging and spectroscopy.
s. 2001. [39] Ugurbil K, Toth L, Kim DS. How accurate is magnetic resonance imaging of brain function? Trends Neurosci 2003;26:108–14. [40] Dechent P, Frahm J. Direct mapping of ocular dominance columns in human primary visual cortex. Neuroreport 2000;11:3247–9. [41] Menon RS, Goodyear BG. Submillimeter functional localization in human striate cortex using BOLD contrast at 4 Tesla: implications...
متن کاملImproving high-field MRI using parallel excitation
MRI at high magnetic field strengths promises to deliver clearer images of the body’s structure and function. However, high-field MRI currently faces several substantial engineering challenges before it can be considered robust and safe enough for routine clinical use. Challenges include increased radiofrequency (RF) energy deposition that can create unsafe patient heating, large main field inh...
متن کاملWide-field Magnetic Field Imaging with Nitrogen
The nitrogen vacancy center (NV) is a promising single spin system in diamond with optical polarization, readout and optically detected magnetic resonances (ODMR). The NV has been shown to be a sensitive magnetometer at room temperature. In particular, owing to their small size, NV centers in nanocrystals (nanodiamonds) offer magnetic field imaging with high spatial resolution. Competitive magn...
متن کاملCommissioning and quality control of a dedicated wide bore 3T MRI simulator for radiotherapy planning
Cite this article as: Xing A, Holloway L, Arumugam S, Walker A, Rai R, Juresic E, Cassapi L, Goozee G, Liney G. Commissioning and quality control of a dedicated wide bore 3T MRI simulator for radiotherapy planning. Int J Cancer Ther Oncol. 2016; 4(2):421. DOI: 10.14319/ijcto.42.1 © Xing et al. ISSN 2330-4049 Commissioning and quality control of a dedicated wide bore 3T MRI simulator for radioth...