Passive neutron area monitor with pairs of TLDs as neutron detector
نویسندگان
چکیده
منابع مشابه
Passive neutron area monitor with CR39
Background: In high-intensity, mixed and pulsed neutron fields the use of spectrometers or area monitors with active detectors is useless in these conditions neutron measuring devices must have a passive detector. Here a passive neutron area monitor with CR39 track detector was designed and the response was calculated. Materials and Methods: The response of a passive neutron area monitor with C...
متن کاملpassive neutron area monitor with cr39
background: in high-intensity, mixed and pulsed neutron fields the use of spectrometers or area monitors with active detectors is useless in these conditions neutron measuring devices must have a passive detector. here a passive neutron area monitor with cr39 track detector was designed and the response was calculated. materials and methods: the response of a passive neutron area monitor with c...
متن کاملSimulation of a Neutron Detector for Real Time Imaging Applications
Monte Carlo Method is used to simulate a double layer gadolinium-amorphous silicon thermal neutron detector. The detector fabricated in pixel array configuration has various applications including neutron imaging. According to the simulation results, a detector consisting of a gadolinium (Gd) film with thickness of 2-4 ~m, sandwiched properly with two layers of sufficiently thick (-30 ?µm) hydr...
متن کاملNeutron Monitor Response Functions
The neutron monitor provides continuous ground-based recording of the hadronic component in atmospheric secondary radiation which is related to primary cosmic rays. Simpson (1948) discovered that the latitude variation of the secondary hadronic component was considerably larger than the muon component suggesting the response of a neutron monitor is more sensitive to lower energies in the primar...
متن کاملDesign and calibration of a passive detector for separating neutron, proton and alpha particles in mixed radiation fields
In this study, calibration process was carried out for deigned new CR-39 nuclear track detector for protons, neutrons and alpha particles separately under the same etching condition. In order to aim this purpose, americium-beryllium standard source (241Am-Be) and Plexiglas phantom for neutron irradiation, brass collimators and americium standard source (241Am) for alpha irradiation and the acce...