Particle number to volume concentration ratios at two measurement sites in Finland
نویسندگان
چکیده
منابع مشابه
New particle formation in air mass transported between two measurement sites in Northern Finland
This study covers four years of aerosol number size distribution data from Pallas and Värriö sites 250 km apart from each other in Northern Finland and compares new particle formation events between these sites. In air masses of eastern origin almost all events were observed to start earlier at the eastern station Värriö, whereas in air masses of western origin most of the events were observed ...
متن کاملA method for bubble volume measurement under constant flow conditions in gas–liquid two-phase flow
Measuring the volume of a bubble, especially at its detachment, is a basic subject in gas-liquid two-phase flow research. A new indirect method for this measurement under constant flow conditions is presented. An electronic device is designed and constructed based on laser beam intensity. This device calculates the frequency of the bubble formation by measuring the total time of the formation p...
متن کاملReliability of hematoma volume measurement at local sites in a multicenter acute intracerebral hemorrhage clinical trial.
BACKGROUND AND PURPOSE The reliability of hematoma volume (HV) measurement using the ABC/2 method in multicenter clinical trials is unknown. We determined the accuracy of ABC/2 method as an on-site test in comparison with the gold standard central HV-assessment and semiautomatic HV-assessment. Method- We analyzed data from an acute intracerebral hemorrhage multicenter clinical trial. HV was mea...
متن کاملImpedance-based Droplet Volume and Concentration Measurement in Digital Microfluidics
MEASUREMENT IN DIGITAL MICROFLUIDICS Gaurav J. Shah, Saman Sadeghi, Huijiang Ding, Supin Chen,, R. Michael van Dam Crump Institute for Molecular Imaging and Department of Molecular & Medical Pharmacology, Biomedical Engineering Department, University of California, Los Angeles, USA ABSTRACT In this paper, we report on simplified and improved impedance detection in digital microfluidics for meas...
متن کاملDiltiazem Co-Treatment in Renal Transplant Patients Receiving Cyclosporine with Respect to Concentration at Two Hours (C2)
Cyclosporine (CsA) is a drug that has been used for prevention of kidney transplant rejection for many years. Diltiazem with the inhibition of cyclosporine metabolism and clearance will increase CsA concentration and CsA dose can be decreased. The aim of this study was the evaluation of diltiazem effect on CsA dose adjustment with respect to C2. Forty stable renal transplant p...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
ژورنال
عنوان ژورنال: Journal of Geophysical Research
سال: 2007
ISSN: 0148-0227
DOI: 10.1029/2006jd007102